; ; COMPAQ Intelligent Drive Array Controller-2 ; BOARD ID="CPQ4002" NAME="COMPAQ Intelligent Drive Array Controller-2" MFR="COMPAQ" CATEGORY="MSD" SLOT=EISA LENGTH=330 READID=YES AMPERAGE=2310 BUSMASTER=200 VERSION=1.2AH REV=0 IOCHECK=INVALID DISABLE=UNSUPPORTED IOPORT(1)=0zCC0h INITVAL=xxxxx0xx IOPORT(2)=11F1h INITVAL=rrrrxxxx IOPORT(3)=1171h INITVAL=rrrrxxxx INCLUDE="CPQ4002.OVL" BEGINOVL GROUP="Controller Characteristics" FUNCTION="Operating System" TYPE="MSD,DSKCTL" HELP="The operating system that you select determines how the COMPAQ Intelligent Drive Array Controller-2 distributes data across the physical disks of this logical drive. The optimum distribution scheme is selected to maximize performance for your operating system. By distributing data, the COMPAQ IDA-2 is able to service multiple requests for data at the same time." CHOICE="NetWare" CHOICE="UNIX/XENIX" CHOICE="OS/2" CHOICE="Banyan VINES" CHOICE="DOS" CHOICE="Other OS" FUNCTION="Fixed Disk Standard Interface" TYPE="MSD,DSKCTL" RESOURCE="ADDRESS",COMMON,LOCAL HELP="The COMPAQ Intelligent Drive Array Controller-2 supports both the Standard Interface and the COMPAQ Bus Master Interface. The Standard Interface can be enabled at the primary address, enabled at the secondary address, or disabled. The Bus Master Interface is always available to any operating system with Bus Master support (such as NetWare and OS/2 Version 1.2)." CHOICE="Primary Address" HELP="To boot from the COMPAQ Intelligent Drive Array Controller-2, enable the Standard Interface at the primary address. The operating system uses the Standard Interface when booting, then switches to the Bus Master Interface if it has the required device driver support." FREE MEMBER="ADDRESS","PRIMARY" IRQ=14 PORT=01F0h-01F7h PORT=03F6h-03F7h SHARE="MSD" PORT=11F1h INIT=IOPORT(1)LOC(1 0)01 INIT=IOPORT(2)LOC(3-0)0100 CHOICE="Secondary Address" HELP="Operating systems without Bus Master Interface support use the Standard Interface after booting. This interface is compatible with COMPAQ and other Industry Standard fixed-disk controllers. The Standard Interface is a system resource that is nonshareable and exclusively allocated." LINK IRQ=11|10|15 INIT=IOPORT(3)LOC(3-0)0001|0010|1000 FREE MEMBER="ADDRESS","SECONDARY" PORT=0170h-0177h PORT=0376h-0377h SHARE="MSD" PORT=1171h INIT=IOPORT(1)LOC(1 0)11 CHOICE="Disabled" HELP="The only time you would disable the Standard Interface is when adding other fixed-disk drives or controllers that require the primary and secondary controller resources. For example, if adding two COMPAQ Advanced ESDI controllers, the COMPAQ Intelligent Drive Array Controller-2's Standard Interface must be disabled so that the ESDI controllers can be enabled at the primary and secondary addresses. The system would boot from one of the Advanced ESDI drives. Because the Standard Interface has been disabled for the COMPAQ IDA-2, your operating system must have a Bus Master Interface device driver." DISABLE=YES FREE MEMBER="ADDRESS","SECONDARY" INIT=IOPORT(1)LOC(1 0)00 FUNCTION="Bus Master Interface" TYPE="MSD,DSKCTL;BMIC" HELP="Bus Master interrupts are used by device drivers written specifically for the COMPAQ Intelligent Drive Array Controller-2. Boards that use level sensitive interrupts may share this interrupt for multiple devices. \n\nThe COMPAQ IDA-2 may be configured to use both a Standard Interface interrupt (such as Primary/IRQ 14, or Secondary/IRQ 10, 11 or 15) for non-bus master device drivers AND a level sensitive Bus Master interrupt for device drivers that understand interrupt sharing." CHOICE="IRQ 15" LINK IRQ=15 SHARE="DARRAY" TRIGGER=LEVEL INIT=IOPORT(1)LOC(7-4)1000 CHOICE="IRQ 14" LINK IRQ=14 SHARE="DARRAY" TRIGGER=LEVEL INIT=IOPORT(1)LOC(7-4)0100 CHOICE="IRQ 11" LINK IRQ=11 SHARE="DARRAY" TRIGGER=LEVEL INIT=IOPORT(1)LOC(7-4)0001 CHOICE="IRQ 10" LINK IRQ=10 SHARE="DARRAY" TRIGGER=LEVEL INIT=IOPORT(1)LOC(7-4)0010 FUNCTION="" SHOW=NO CHOICE="" FUNCTION="Controller Order" TYPE="MSD,DSKCTL;CTLID" HELP="When adding a controller to a configured system, you can either place it at the end of the controller order or reorder the controllers. Reordering changes the current drive letter assignments for all drives on the system. To avoid changing the drive letter assignments when you add a controller to a configured system, place it at the end of the controller order and DO NOT CREATE A PRIMARY PARTITION on any of the added disks." RESOURCE="CNTRORD",UNIQUE CHOICE="First" LINK MEMBER="CNTRORD","1" SHARE=NO MEMBER="ADDRESS","PRIMARY" CHOICE="Second" LINK MEMBER="CNTRORD","2" SHARE=NO MEMBER="ADDRESS","SECONDARY" CHOICE="Third" LINK MEMBER="CNTRORD","3" SHARE=NO MEMBER="ADDRESS","SECONDARY" CHOICE="Fourth" LINK MEMBER="CNTRORD","4" SHARE=NO MEMBER="ADDRESS","SECONDARY" CHOICE="Fifth" LINK MEMBER="CNTRORD","5" SHARE=NO MEMBER="ADDRESS","SECONDARY" CHOICE="Sixth" LINK MEMBER="CNTRORD","6" SHARE=NO MEMBER="ADDRESS","SECONDARY" CHOICE="Seventh" LINK MEMBER="CNTRORD","7" SHARE=NO MEMBER="ADDRESS","SECONDARY" CHOICE="Eighth" LINK MEMBER="CNTRORD","8" SHARE=NO MEMBER="ADDRESS","SECONDARY" ENDGROUP GROUP="Drive Characteristics" FUNCTION="Logical Drive 1" HELP="Each Logical Drive on the COMPAQ Intelligent Drive Array Controller-2 appears as a physical drive to your operating system. The number of physical drive pairs and fault tolerance are specified to configure each Logical Drive." TYPE="MSD,UNIT0,DSKDRV" CHOICE="" FUNCTION="Logical Drive 2" HELP="Each Logical Drive on the COMPAQ Intelligent Drive Array Controller-2 appears as a physical drive to your operating system. The number of physical drive pairs and fault tolerance are specified to configure each Logical Drive." TYPE="MSD,UNIT1,DSKDRV" CHOICE="" FUNCTION="Logical Drive 3" HELP="Each Logical Drive on the COMPAQ Intelligent Drive Array Controller-2 appears as a physical drive to your operating system. The number of physical drive pairs and fault tolerance are specified to configure each Logical Drive." TYPE="MSD,UNIT2,DSKDRV" CHOICE="" FUNCTION="" SHOW=NO CHOICE="" LINK INIT=PORTADR(0zC89h) 00000000 FUNCTION="Unused Drive Pairs" HELP="Unused Drive Pairs shows any physical drive pairs not assigned to a logical drive. \n\nTo use these drive pairs, increase the number of drives assigned to a logical drive or configure a second logical drive. \n\nTo increase the number of unused drive pairs, you must decrease the number of drives assigned to a logical drive or physically install more drives." CHOICE="" FUNCTION="" TYPE="" SHOW=NO CHOICE="" FUNCTION = "" TYPE="" SHOW=NO CHOICE="" FUNCTION = "" TYPE="" SHOW=NO CHOICE="" ENDGROUP FUNCTION = "" SHOW=NO CHOICE="" FREE INIT=IOPORT(1)LOC(3)1 CHOICE="" FREE INIT=IOPORT(1)LOC(3)0 GROUP="Array Accelerator Status" FUNCTION="Logical Drive 1" CHOICE="" CHOICE="" FUNCTION="Logical Drive 2" CHOICE="" CHOICE="" FUNCTION="Logical Drive 3" CHOICE="" CHOICE="" ENDGROUP GROUP="Advanced Features" FUNCTION="Reset Configuration" TYPE="MSD,DSKCTL" SHOW=EXP CHOICE="Not Reset" CHOICE="Reset" FUNCTION="Striping Factor - Logical Drive 1" TYPE="MSD,DSKCTL" SHOW=EXP CHOICE="8" CHOICE="16" FUNCTION="Striping Factor - Logical Drive 2" TYPE="MSD,DSKCTL" SHOW=EXP CHOICE="8" CHOICE="16" FUNCTION="Striping Factor - Logical Drive 3" TYPE="MSD,DSKCTL" SHOW=EXP CHOICE="8" CHOICE="16" ENDGROUP ENDOVL