BOARD ID = "NICC005" NAME = "National Instruments AT-GPIB Interface Board" MFR = "NATIONAL INSTR CORP" CATEGORY = "COM" SLOT = ISA16 READID = NO LENGTH = 165 ;16.5cm = 6.5inches AMPERAGE = 1500 ;1.5 Amps SKIRT = NO COMMENTS = "AT-GPIB EISA configuration file Version 3.0; For further information call National Instruments at 1-800-433-3488." HELP = "Sorry, no help available." SWITCH(1) = 5 NAME = "Base I/O Address" STYPE = DIP VERTICAL = YES REVERSE = YES LABEL = LOC(1-5) "9" "8" "7" "6" "5" FACTORY = LOC(1-5) 01001 COMMENTS = "The base I/O address is determined by the settings of the DIP switch (U25). Note that this switch uses negative logic. If your screen or report shows you a binary representation of the switch, the ones and zeroes will be reversed. The 'ON' and 'OFF' settings given by the configuration utility are correct." JUMPER(1) = 11 NAME = "DMA/High IRQ (W2)" JTYPE = PAIRED VERTICAL = NO REVERSE = YES LABEL = LOC(1-11) "DRQ7" "DACK7" "DRQ6" "DACK6" "DRQ5" "DACK5" "IRQ15" "IRQ14" "IRQ12" "IRQ11" "IRQ10" FACTORY = LOC(1-11) 00001100010 ;Factory defaults - DACK5,DRQ5, and IRQ11 COMMENTS = "The DMA channel used is determined by this jumper. Note that both DRQ (request) and DACK (acknowledge) jumpers must be set to the same channel if that channel is to be used. In addition, the high IRQ levels (10, 11, 12, 14, and 15) are selected by this jumper." JUMPER(2) = 6 NAME = "Low IRQ Level (W3)" JTYPE = PAIRED VERTICAL = NO REVERSE = YES LABEL = LOC(1-6) "IRQ3" "IRQ4" "IRQ5" "IRQ6" "IRQ7" "IRQ9" FACTORY = LOC(1-6) 000000 ;Factory default is IRQ11 COMMENTS = "The low IRQ levels (3, 4, 5, 6, 7, and 9) are selected by this jumper. Only one of the high IRQ or low IRQ levels should be selected." FUNCTION = "AT-GPIB Interface" SUBFUNCTION = "Base I/O Address" CHOICE = "2C0" LINK PORT = 2C0h-2DFh INIT = SWITCH(1) LOC(1-5) 01001 CHOICE = "2E0" LINK PORT = 2E0h-2FFh INIT = SWITCH(1) LOC(1-5) 01000 CHOICE = "100" LINK PORT = 100h-11Fh INIT = SWITCH(1) LOC(1-5) 10111 CHOICE = "120" LINK PORT = 120h-13Fh INIT = SWITCH(1) LOC(1-5) 10110 CHOICE = "140" LINK PORT = 140h-15Fh INIT = SWITCH(1) LOC(1-5) 10101 CHOICE = "160" LINK PORT = 160h-17Fh INIT = SWITCH(1) LOC(1-5) 10100 CHOICE = "180" LINK PORT = 180h-19Fh INIT = SWITCH(1) LOC(1-5) 10011 CHOICE = "1A0" LINK PORT = 1A0h-1BFh INIT = SWITCH(1) LOC(1-5) 10010 CHOICE = "1C0" LINK PORT = 1C0h-1DFh INIT = SWITCH(1) LOC(1-5) 10001 CHOICE = "1E0" LINK PORT = 1E0h-1FFh INIT = SWITCH(1) LOC(1-5) 10000 CHOICE = "200" LINK PORT = 200h-21Fh INIT = SWITCH(1) LOC(1-5) 01111 CHOICE = "220" LINK PORT = 220h-23Fh INIT = SWITCH(1) LOC(1-5) 01110 CHOICE = "240" LINK PORT = 240h-25Fh INIT = SWITCH(1) LOC(1-5) 01101 CHOICE = "260" LINK PORT = 260h-27Fh INIT = SWITCH(1) LOC(1-5) 01100 CHOICE = "280" LINK PORT = 280h-29Fh INIT = SWITCH(1) LOC(1-5) 01011 CHOICE = "2A0" LINK PORT = 2A0h-2BFh INIT = SWITCH(1) LOC(1-5) 01010 CHOICE = "300" LINK PORT = 300h-31Fh INIT = SWITCH(1) LOC(1-5) 00111 CHOICE = "320" LINK PORT = 320h-33Fh INIT = SWITCH(1) LOC(1-5) 00110 CHOICE = "340" LINK PORT = 340h-35Fh INIT = SWITCH(1) LOC(1-5) 00101 CHOICE = "360" LINK PORT = 360h-37Fh INIT = SWITCH(1) LOC(1-5) 00100 CHOICE = "380" LINK PORT = 380h-39Fh INIT = SWITCH(1) LOC(1-5) 00011 CHOICE = "3A0" LINK PORT = 3A0h-3BFh INIT = SWITCH(1) LOC(1-5) 00010 CHOICE = "3C0" LINK PORT = 3C0h-3DFh INIT = SWITCH(1) LOC(1-5) 00001 CHOICE = "3E0" LINK PORT = 3E0h-3FFh INIT = SWITCH(1) LOC(1-5) 00000 SUBFUNCTION = "DMA Channel" CHOICE = "5" LINK DMA = 5 SHARE = NO TIMING = TYPEB INIT = JUMPER(1) LOC(1-6) 000011 CHOICE = "6" LINK DMA = 6 SHARE = NO TIMING = TYPEB INIT = JUMPER(1) LOC(1-6) 001100 CHOICE = "7" LINK DMA = 7 SHARE = NO TIMING = TYPEB INIT = JUMPER(1) LOC(1-6) 110000 CHOICE = "Disabled" LINK INIT = JUMPER(1) LOC(1-6) 000000 SUBFUNCTION = "Interrupt Request Level" CHOICE = "11" LINK IRQ = 11 SHARE = NO TRIGGER = EDGE INIT = JUMPER(1) LOC(7-11) 00010 INIT = JUMPER(2) LOC(1-6) 000000 CHOICE = "10" LINK IRQ = 10 SHARE = NO TRIGGER = EDGE INIT = JUMPER(1) LOC(7-11) 00001 INIT = JUMPER(2) LOC(1-6) 000000 CHOICE = "5" LINK IRQ = 5 SHARE = NO TRIGGER = EDGE INIT = JUMPER(2) LOC(1-6) 001000 INIT = JUMPER(1) LOC(7-11) 00000 CHOICE = "7" LINK IRQ = 7 SHARE = NO TRIGGER = EDGE INIT = JUMPER(2) LOC(1-6) 000010 INIT = JUMPER(1) LOC(7-11) 00000 CHOICE = "9" LINK IRQ = 9 SHARE = NO TRIGGER = EDGE INIT = JUMPER(2) LOC(1-6) 000001 INIT = JUMPER(1) LOC(7-11) 00000 CHOICE = "12" LINK IRQ = 12 SHARE = NO TRIGGER = EDGE INIT = JUMPER(1) LOC(7-11) 00100 INIT = JUMPER(2) LOC(1-6) 000000 CHOICE = "3" LINK IRQ = 3 SHARE = NO TRIGGER = EDGE INIT = JUMPER(2) LOC(1-6 ) 100000 INIT = JUMPER(1) LOC(7-11) 00000 CHOICE = "4" LINK IRQ = 4 SHARE = NO TRIGGER = EDGE INIT = JUMPER(2) LOC(1-6) 010000 INIT = JUMPER(1) LOC(7-11) 00000 CHOICE = "14" LINK IRQ = 14 SHARE = NO TRIGGER = EDGE INIT = JUMPER(1) LOC(7-11) 01000 INIT = JUMPER(2) LOC(1-6) 000000 CHOICE = "15" LINK IRQ = 15 SHARE = NO TRIGGER = EDGE INIT = JUMPER(1) LOC(7-11) 10000 INIT = JUMPER(2) LOC(1-6) 000000 CHOICE = "6" LINK IRQ = 6 SHARE = NO TRIGGER = EDGE INIT = JUMPER(1) LOC(7-11) 00000 INIT = JUMPER(2) LOC(1-6) 000100 CHOICE = "Disabled" LINK INIT = JUMPER(1) LOC(7-11) 00000 INIT = JUMPER(2) LOC(1-6) 000000