SYMPTOMS
========
The Microsoft Macro Assembler will generate a misleading error message when a
segment with the AT combine type is specified with a segment value that is too
large. The error message generated will be:
error A2029: Division by 0 or overflow
It is not clear from the error message that the segment value was too large.
CAUSE
=====
This is the expected behavior of MASM 5.0, 5.1, and 5.1a.
RESOLUTION
==========
MASM 6.0 now generates the following error message:
error A2084: constant value too large
MORE INFORMATION
================
The following sample code can be used to demonstrate the problem.
Sample Code
-----------
; Assemble options needed: none
S1 SEGMENT AT 01234H ; This segment is OK
S2 ENDS
S2 SEGMENT AT 12345H ; This segment generates a misleading error
S2 ENDS
END