Article: Q67777
Product(s): Microsoft Programming Utilities
Version(s): OS/2:1.0,1.1
Operating System(s):
Keyword(s): kb16bitonly
Last Modified: 31-OCT-1999
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Programmer's Workbench for OS/2, versions 1.0, 1.1
-------------------------------------------------------------------------------
SYMPTOMS
========
When attempting to load an OS/2 Programmer's WorkBench (PWB) extension through a
macro definition in the TOOLS.INI file, if the extension file does not exist, or
is not in the current path, the following error message is displayed in a dialog
box:
pwbhelp: SYS0123: A file name or volume label contains an incorrect character
CAUSE
=====
This error message should indicate that the extension file could not be found;
however, the message is generated by the OS/2 operating system's DLL loading
code, and therefore, cannot be changed by PWB.
The following error message is generated in the MS-DOS version of PWB, which
displays this message in a dialog box:
No such file or directory
RESOLUTION
==========
To correct the problem, make sure that the directory in which the extension
resides is in the current path.
Additional query words: 1.00 1.10 PWBIss
======================================================================
Keywords : kb16bitonly
Technology : kbAudDeveloper kbPWBSearch kbZNotKeyword3 kbPWB100OS2 kbPWB110OS2
Version : OS/2:1.0,1.1
=============================================================================