Article: Q69185
Product(s): Microsoft Windows 95.x Retail Product
Version(s): WINDOWS:3.0,3.0a
Operating System(s):
Keyword(s):
Last Modified: 02-NOV-1999
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows versions 3.0, 3.0a
-------------------------------------------------------------------------------
SYMPTOMS
========
If you load EMM386.SYS in the CONFIG.SYS file, run Microsoft LAN Manager version
2.0 enhanced as your network, and try to start Microsoft Windows version 3.0
with the WIN /S switch, you may get the following error message:
Cannot run Windows in Standard Mode. Check to ensure you are not running
other protected-mode software, or run in real mode.
WORKAROUND
==========
To allow standard mode to run, do one of the following:
- Remove or comment out the line in the [workstation] section of your
LANMAN.INI file that reads
LIM=YES
-or-
- Make a boot disk with a CONFIG.SYS file that does not load EMM386.SYS if you
want to use standard mode.
Additional query words: 3.00 3.0 3.0a 3.00a
======================================================================
Keywords :
Technology : kbWin3xSearch kbZNotKeyword3 kbWin300 kbWin300a