Article: Q87984
Product(s): Microsoft Windows 95.x Retail Product
Version(s): WINDOWS:3.0,3.0a,3.1,3.11
Operating System(s):
Keyword(s):
Last Modified: 17-OCT-1999
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows versions 3.0, 3.0a, 3.1, 3.11
-------------------------------------------------------------------------------
SYMPTOMS
========
If Microsoft Windows is running on a Novell workstation in 386 enhanced mode
while connected to a Novell server, and the server stops functioning and/or
disconnects the workstation, then the workstation may hang and display the error
message:
System Error cannot read from device network.
This occurs even if Windows is installed in a standalone configuration. Novell is
aware of the problem and is working to correct this.
WORKAROUND
==========
To work around this problem run Windows in standard mode.
The NetWare product included here is manufactured by a vendor independent of
Microsoft; we make no warranty, implied or otherwise, regarding this product's
performance or reliability.
Additional query words: 3.00 3.00a 3.10 stand alone stand-alone
======================================================================
Keywords :
Technology : kbWin3xSearch kbZNotKeyword3 kbWin300 kbWin300a kbWin310 kbWin311
Version : WINDOWS:3.0,3.0a,3.1,3.11
=============================================================================