Article: Q92881
Product(s): Microsoft Windows 3.x Retail Product
Version(s): WINDOWS:3.1,3.11
Operating System(s):
Keyword(s):
Last Modified: 30-SEP-1999
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows for Workgroups versions 3.1, 3.11
-------------------------------------------------------------------------------
SYMPTOMS
========
If you install Windows for Workgroups on a machine that was once an IBM OS/2 Lan
Server client, you may receive a "Netbind" error followed by an "Undefined
Dynalink" error when you start Windows for Workgroups.
CAUSE
=====
These errors indicate that there are still IBM Lan Server drivers in the
CONFIG.SYS and AUTOEXEC.BAT files.
RESOLUTION
==========
The following lines need to be removed or remarked out (using REM) from the
CONFIG.SYS file:
- Any lines that reference PROTMAN.EXE (Windows for Workgroups uses
PROTMAN.DOS)
- Any lines that reference DXMEOMOD.SYS
In the AUTOEXEC.BAT file, any reference to the Lan Server software directory in
the PATH= statement should be removed.