Article: Q99197
Product(s): Microsoft LAN Manager
Version(s):
Operating System(s):
Keyword(s):
Last Modified: 19-FEB-2002
SYMPTOMS
========
LAN Manager servers receive an error 5325 (duplicate name found) or error 3172
(error sending alert message) along with error 2136 (Trap00D, Trap00C--general
network error). Primary server traps result in a ring0 error and complete loss
of functionality, although member servers also are trapped along with the
primary.
CAUSE
=====
Updated revision display level required.
RESOLUTION
==========
Update the display revision level from 1.02 files dated 10/1/90 to 1.03 dated
10/31/91 or later ones using the reference disk.
CONFIGURATION
-------------
The problem was reported on this configuration:
LAN Manager 2.2
OS/2 1.3
net card IBM 16 token ring
IBM model 95 486 server
HPFS386
user level security
NetBEUI.
Additional query words:
======================================================================