SYMPTOMS
========
When an application developed in Microsoft FORTRAN PowerStation runs on a
computer that does not have a math coprocessor installed, the code may convert a
REAL variable or expression to an INTEGER variable incorrectly, resulting in
incorrect results.
CAUSE
=====
When an application immediately converts the results of a REAL calculation to an
INTEGER value, the code does not remove the results from the coprocessor
emulator stack. The numeric conversion routine __ftol (float to long) uses this
extended coprocessor-stack-based value instead of the truncated contents stored
in the variable. The __ftol function incorrectly rounds down the
extended-precision result.
RESOLUTION
==========
To work around this problem, use the NINT (round to nearest integer) intrinsic
function to explicitly convert the expression or variable to an INTEGER.
The /Ox optimization compiler option switch may resolve this error. Among other
optimizations, the /Ox switch calculates constant expressions at compile time.
These calculations may correctly convert the REAL number to an INTEGER while the
run-time calculation produces the incorrectly rounded result.
STATUS
======
Microsoft has confirmed this to be a problem in PowerStation versions 1.0 and
1.0a for MS-DOS. This problem has been resolved with FORTRAN PowerStation
maintenance release version 1.0a for MS-DOS.
FORTRAN Powerstation version 1.0 can be differentiated from the maintenance
release version 1.0a by invoking the linker. Typing "link32 | more" from the
\f32\BIN directory will show version 2.8 for FORTRAN Powerstation version 1.0,
and it will show 1.0f for the maintenance release version 1.0a.
MORE INFORMATION
================
The FORTRAN PowerStation floating-point emulator is a virtual dynamic- link
library (DLL) in the Phar Lap MS-DOS extender. To duplicate this problem on a
computer with a math coprocessor installed, type the following at the MS-DOS
command prompt:
SET TNT=-FPEM
This statement causes the MS-DOS extender to ignore the math coprocessor and use
the emulator code for all math operations.
The following code example prints the word "Failed" when it runs with the
floating-point emulator:
Sample Code 1
-------------
C Compiler options needed: none
x = 3.0
z = -3. ** x
i = z
if (i .ne. -27) then
print *, 'Failed'
else
print *, 'OK'
end if
end
The following code example demonstrates using the NINT intrinsic function to
avoid this error. This code prints the word "OK" even when a math coprocessor is
not available.
Sample Code 2
-------------
C Compiler options needed: none
x = 3.0
z = -3. ** x
i = nint(z)
if (i .ne. -27) then
print *, 'Failed'
else
print *, 'OK'
end if
end
Additional query words: 1.00 Phar Lap DOSXMSF.EXE
======================================================================
Keywords :
Technology : kbAudDeveloper kbFortranSearch kbZNotKeyword3
Version : :
Issue type : kbbug
Solution Type : kbfix
=============================================================================