SYMPTOMS
========
When an attempt is made to build or debug an application from the Visual
Workbench, a dialog box with the following message may appear:
Start-up directory not found
Check the application's PIF
CAUSE
=====
The entry for the startup directory in the WINTEE.PIF is always \F32\BIN even if
the product was installed in another directory. This causes an error when an
application is built, if the Visual Workbench is started with /v option to make
WINTEE.EXE visible.
RESOLUTION
==========
To correct this problem:
1. Run the Windows PIF Editor.
2. Open the file \F32\BIN\WINTEE.PIF.
3. Correct the startup directory (it will probably show the default directory).
4. Save changes in the PIF Editor.
5. Compiling should work fine now (there is no need to restart Windows or the
Visual Workbench).
STATUS
======
Microsoft has confirmed this to be a problem in FORTRAN PowerStation versions
1.0 and 1.0a for MS-DOS.
This is not a problem in FORTRAN PowerStation 32.
MORE INFORMATION
================
The /v option when invoking the Visual Workbench makes WINTEE MS-DOS box
visible.
Additional query words: VWB nofpsnt
======================================================================