Article: Q109536
Product(s): Microsoft Windows 95.x Retail Product
Version(s): WINDOWS:3.1,3.11
Operating System(s):
Keyword(s):
Last Modified: 09-OCT-1999
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows versions 3.1, 3.11
- Microsoft Windows for Workgroups versions 3.1, 3.11
-------------------------------------------------------------------------------
SYMPTOMS
========
If you include any parameters on your SET COMSPEC command (typically located in
the AUTOEXEC.BAT file), you receive the following error message when you try to
start MS-DOS-based applications under Windows or Windows for Workgroups:
Cannot start application
WORKAROUND
==========
To work around this problem, edit your AUTOEXEC.BAT file and remove any
parameters from your SET COMSPEC command.
MORE INFORMATION
================
Any configuration parameters for COMMAND.COM should be placed on the SHELL= line
in the CONFIG.SYS file. For example:
shell=c:\dos\command.com c:\dos\ /e:512 /p
Additional query words: 3.10 3.1 3.11
======================================================================
Keywords :
Technology : kbAudDeveloper kbWin3xSearch kbWFWSearch kbZNotKeyword3 kbWin310 kbWin311 kbWFW310 kbWFW311