Article: Q130418
Product(s): Microsoft Windows NT
Version(s):
Operating System(s):
Keyword(s):
Last Modified: 08-AUG-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows NT Workstation version 3.5
- Microsoft Windows NT Server version 3.5
-------------------------------------------------------------------------------
SYMPTOMS
========
If you run WINNT.EXE and SMARTDrive (SMARTDRV.EXE) is loaded to cache reads and
writes to drive A, and you follow the Setup prompts, the first floppy disk is
removed before MS-DOS has finished writing to the floppy disk. This results in
various problems and the wrong files being written to the setup disks.
CAUSE
=====
The cached data is not flushed to the floppy disk before you are prompted to
change floppy disks.
STATUS
======
Microsoft has confirmed this to be a problem in Windows NT version 3.5. This
problem was corrected in Windows NT version 3.51.
Additional query words: prodnt 3.51
======================================================================
Keywords :
Technology : kbWinNTsearch kbWinNTWsearch kbWinNT350search kbWinNTW350 kbWinNTW350search kbWinNTSsearch kbWinNTS350 kbWinNTS350search
=============================================================================