Article: Q135385
Product(s): Microsoft FoxPro
Version(s): WINDOWS:3.0
Operating System(s):
Keyword(s): kbbuglist kbfixlist
Last Modified: 24-MAR-2000
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Visual FoxPro for Windows, version 3.0
-------------------------------------------------------------------------------
SYMPTOMS
========
After suspending an error, using the CLEAR ALL command produces this error:
Cannot clear the object in use.
Using the CANCEL command after this error causes Visual FoxPro to close (crash).
This happens only after using a version 2.x READ WHEN command.
WORKAROUND
==========
There is no problem if you reverse the command sequence:
CANCEL
* Click OK to clear the "Cannot clear object in use" error message.
CLEAR ALL
STATUS
======
Microsoft has confirmed this to be a problem in the Microsoft products listed at
the beginning of this article. This problem was corrected in Visual FoxPro 3.0b
for Windows.
MORE INFORMATION
================
Code to Reproduce Problem
-------------------------
DEFINE WINDOW one FROM 1,1 TO 20,20 FLOAT
ACTIVATE WINDOW one
@ 1,1 GET x DEFA 1 NAME bob
READ WHEN test()
PROC test
jhjhj && Random characters to generate error
* When the error dialog appears, select SUSPEND
* In the Command window, enter the following lines of code:
CLEAR ALL
* Click OK to clear the "Cannot clear object in use" error message.
CANCEL
Additional query words: 3.00 3.00b VFoxWin fixlist3.00b buglist3.00
======================================================================
Keywords : kbbuglist kbfixlist
Technology : kbVFPsearch kbAudDeveloper kbVFP300
Version : WINDOWS:3.0
Issue type : kbbug
Solution Type : kbfix
=============================================================================