SUMMARY
=======
By default, the SNA Server TN3270 server allows a client to connect using any
port value and IP address. While it is possible to configure the range of IP
addresses that have access to a pool or LU, TN3270 server always hard codes the
port value range to (00000, 65535). There is no way to change this using the
TN3270 Admin program.
WORKAROUND
==========
To implement checking on a given port range, the TN3270 server configuration
file (TNSVRCFG.TNC) must be manually edited.
For example:
This sample TN3270 configuration file shows one TN3270 pool configured to allow
any client Internet protocol address or client port number access to the LUA LUs
in the pool.
[SNA Resource 1]
Name=TNTEST
Sessions=16
MaxSessions=16
TerminalName1=IBM-3276-3
TerminalName2=IBM-3278-3
TerminalName3=IBM-3278-3-E
TerminalName4=IBM-3279-3
TerminalName5=IBM-3279-3-E
[Group 1]
Name=TNTEST
Comment=
SNAResource1=TNTEST
IPConnection1=000.000.000.000,000.000.000.000,00000,65535
To modify the available port numbers change the last two numbers (00000,65535) to
the desired range.
Example Two:
[SNA Resource 1]
Name=TNTEST
Sessions=16
MaxSessions=16
TerminalName1=IBM-3276-3
TerminalName2=IBM-3278-3
TerminalName3=IBM-3278-3-E
TerminalName4=IBM-3279-3
TerminalName5=IBM-3279-3-E
[Group 1]
Name=TNTEST
Comment=
SNAResource1=TNTEST
IPConnection1=000.000.000.000,000.000.000.000,50000,60000
This sets the allowable client port range to 50000-60000. Any client attempting
to connect with a different local port number will be denied. If this occurs,
the following TN3270 errors will occur:
On the client machine:
Warning 512
TN3270 Service Error 512
Access for IP address <client IP address> port <client port
number>
is not configured.
On the server machine:
Warning 603
TN3270 session with client at <client IP address> <port <client
port
number>> using LU <LU name> terminated abnormally because:
Access for IP address <client IP address> <port <client port
number>> is
not configured.
Explanation: A TN3270 client session was terminated abnormally.