Article: Q156298
Product(s): Open Database Connectivity (ODBC)
Version(s): 3.4
Operating System(s):
Keyword(s):
Last Modified: 26-MAR-2000
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft ODBC Desktop Driver version 3.4
-------------------------------------------------------------------------------
SYMPTOMS
========
When you disconnect from an ODBC application that uses Access driver version
3.40 or other ODBC desktop drivers, you may receive the following error
message:
Message Box Title: <appname.exe>
The instruction at <addr1> referenced a memory at <addr2>.
The memory could not be written.
WORKAROUND
==========
This problem has been fixed in Msjt3032.dll version 3.00.3213. For information
on how to obtain this file, see the following article in the Microsoft Knowledge
Base:
Q151186 INF: Updated Jet DLLs Available on MSL
After you download this file, you can copy Msjt3032.dll to your
<%winroot%>\system32 directory.
Additional query words: 3.40 JET MFC exception
======================================================================
Keywords :
Technology : kbAudDeveloper kbODBCSearch kbODBCDDKSearch kbODBCDDK340
Version : :3.4
Issue type : kbbug