SUMMARY
=======

This article pertains to the use of the Error event of a control and the RETURN
TO command when trying to return to a method or event of a form or class that is
different from where the Error event was generated. When using the RETURN TO
command in a form or class, it will only return to the method or event on some
of FoxPro's error messages.

STATUS
======

Microsoft has confirmed this to be a bug in the Microsoft products listed at the
beginning of this article. This bug has been fixed in Visual Studio 97 Service
Pack 2.

For more information on the Visual Studio 97 Service Pack 2, please see the
following article in the Microsoft Knowledge Base:

  Q170365 INFO: Visual Studio 97 Service Packs - What, Where, and Why

MORE INFORMATION
================

The RETURN TO command is useful when the execution of code needs to be
redirected to a method or event further up in the call stack. One reason for
wanting to return to some method or event different from the calling method or
event would be when trying to bypass the remainder of code in the event or
method that is after the line of code that caused the error. For example, a
Click event of the command button might call a method that executes some code.
If this code causes an error, the Error event of the command button could handle
the error and then a RETURN TO command could be used to return to the Click
event of the command button without executing the rest of the code in the method
that it called.

The problem is that this works with only some of the FoxPro commands. For
example, if the line of code that causes the error is "SET FILTER TO 10," the
RETURN TO command does not work correctly. If the line of code is "WAIT WINDOW
10," the RETURN TO command works correctly. Both are syntax errors, but one
works and the other does not.

Steps to Reproduce Behavior
---------------------------

1. Create a form with the form designer and add a command button.

2. Place the following code in the Click event of the command button.

        THISFORM.TriggerError
        ? "After calling the Triggererror method in the command button."

3. In the Error event of the command button, place the following code:

        ? "In the Error event of the command button."
        RETURN TO click

4. Add a custom method to the form call TriggerError.

5. Add the following code to the method TriggerError.

        USE HOME()+"samples\data\customer"
        SET FILTER TO 10
        *WAIT WINDOW 10
        ? "*** After the error code."

6. Run the form and click on the command button.

  Note that the "*** After the error code." message is displayed when the SET
  FILTER TO 10 command triggers an error. Now comment the SET FILTER command
  and uncomment the WAIT WINDOW 10 command. The "*** After the error code."
  message doesn't appear now because execution is returned directly to the
  Click event of the command button.

  Another thing to be aware of is that if there is code in the Error event of
  the form, control will not be returned to the method or event that is
  identified in the RETURN TO command.

Additional query words:

======================================================================
Keywords          : kbvfp kbVS97sp2fix 
Technology        : kbVFPsearch kbAudDeveloper kbVFP300 kbVFP300b kbVFP500 kbVFP500a
Version           : 3.0 5.0
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================