Article: Q157838
Product(s): Microsoft Systems Management Server
Version(s): winnt:1.2
Operating System(s):
Keyword(s): kb3rdparty kbnetwork kbsetup kbsms120 smssetup smshowto
Last Modified: 27-JUL-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Systems Management Server version 1.2
-------------------------------------------------------------------------------
SYMPTOMS
========
Microsoft Windows 95 clients using the Novell Client 32 (the Client32.nlm file,
which has a size of 452,648 bytes) stop responding during the NetWare system
login script.
CAUSE
=====
There is a known problem with running external commands from Client 32, as
documented in the Novell Technical Information Document (TID) 2906860. This
article can be obtained from the Novell web site at http://www.novell.com.
WORKAROUND
==========
A solution is documented in the Novell TID noted above, to allow you to run
external login script commands. If the # command within the login script is not
given an executable file name with an extension (for example, #DOSVER instead of
#DOSVER.COM), the problem will occur.
By modifying the Smsls.scr script, the problem can be alleviated until a newer
version of Client 32 is released.
Modifying Smsls.scr
-------------------
To modify the Smsls.scr file, find it in the Systems Management Server site
server's Sms\Site.srv\Maincfg.box\Client.src directory, and then use the
following steps:
1. Make a backup copy of the Smsls.scr file.
2. Edit the file with any text editor that has a search function, such as
Notepad.
3. Search the Smsls.scr file for instances of the number sign (#).
4. Change the following instances of "#" to their respective modified entries:
#%<SMS_LOGON>\dosver
to:
#%<SMS_LOGON>\dosver.com
#%<SMS_LOGON>\netspeed
to:
#%<SMS_LOGON>\netspeed.com
#%<SMS_LOGON>\x86.bin\NLSMSG16 6 /C YN /T Y,30 /M "Slow network detected. Continue"
to:
#%<SMS_LOGON>\x86.bin\NLSMSG16.EXE 6 /C YN /T Y,30 /M "Slow network detected. Continue"
#%<SMS_LOGON>\x86.bin\CLI_DOS /p:%<SMS_LOGON>\%<SMS_VERBOSE>
to:
#%<SMS_LOGON>\x86.bin\CLI_DOS.EXE /p:<SMS_LOGON>\%<SMS_VERBOSE>
#%<SMS_LOGON>\x86.bin\INVDOS /i /l:%<SMS_LOGON>\%<SMS_VERBOSE>
to:
#%<SMS_LOGON>\x86.bin\INVDOS.EXE /i /l:%<SMS_LOGON>\%<SMS_VERBOSE>
#%<SMS_LOGON>\x86.bin\NLSMSG16 11 /M "This version of SMS does not support Windows NT workstations"
to:
#%<SMS_LOGON>\x86.bin\NLSMSG16.EXE 11 /M "This version of SMS does not support Windows NT workstations"
#%<SMS_LOGON>\x86.bin\NLSMSG16 12 /M "that are clients to a Novell NetWare server."
to:
#%<SMS_LOGON>\x86.bin\NLSMSG16.EXE 12 /M "that are clients to a Novell NetWare server."
#%<SMS_LOGON>\clrlevel
to:
#%<SMS_LOGON>\clrlevel.com
5. Save the file.
The Systems Management Server Maintenance Manager service will then copy the
updated file to your NetWare logon servers.
NOTE: During the execution of the login script, the Client 32 Logon Results
window will display two errors in the form: "Error returned from Dosver &
Cli_dos". These errors can be safely ignored; unfortunately, they cannot be
prevented.
MORE INFORMATION
================
The third-party products discussed in this article are manufactured by vendors
independent of Microsoft; we make no warranty, implied or otherwise, regarding
these products' performance or reliability.
Additional query words: prodsms Novell NLM Client32 hang hangs hung
======================================================================
Keywords : kb3rdparty kbnetwork kbsetup kbsms120 smssetup smshowto
Technology : kbSMSSearch kbSMS120
Version : winnt:1.2
Issue type : kbprb
=============================================================================