Article: Q159627
Product(s): Microsoft SNA Server
Version(s): WINDOWS:3.0
Operating System(s):
Keyword(s): kbnetwork kbsetup
Last Modified: 13-JUN-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft SNA Server, version 3.0, on platform(s):
- the operating system: Microsoft Windows NT
-------------------------------------------------------------------------------
SYMPTOMS
========
TN5250 clients that are connecting to an SNA Server that has connections to
multiple AS/400s cannot specify which AS/400 to connect to.
CAUSE
=====
The TN5250 RFC (RFC 1205) does not include a specification that would allow
TN5250 clients to specify an AS/400 to connect to. Therefore, the TN5250 service
included with SNA Server 3.0 was not designed to support a mechanism that would
allow TN5250 clients to connect to a specific AS/400.
RESOLUTION
==========
To work around this problem:
1. Set up multiple computers running SNA Server and running the TN5250 service.
Each one must have a connection to a different AS/400.
2. Configure the TN5250 client(s) to connect to the TCP/IP Address or Host Name
of the computer running SNA Server that has a connection to the AS/400 that
the client(s) wants to connect to.
NOTE: Only one instance of the TN5250 Server service can be used on a computer
running SNA Server. To support this resolution, multiple computers running SNA
Server must be used, each running a different TN5250 Server service.
STATUS
======
Microsoft has confirmed this to be a problem in SNA Server version 3.0. We are
researching this problem and will post new information here in the Microsoft
Knowledge Base as it becomes available.
Additional query words: manager prodsna
======================================================================
Keywords : kbnetwork kbsetup
Technology : kbAudDeveloper kbSNAServSearch