Article: Q170808
Product(s): Microsoft Windows NT
Version(s): 3.50 3.51 4.00 95 3.11
Operating System(s):
Keyword(s):
Last Modified: 10-AUG-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows NT Workstation versions 3.5, 3.51, 4.0
- Microsoft Windows NT Server versions 3.5, 3.51, 4.0
- Microsoft Windows for Workgroups version 3.11
- Microsoft Windows 95
-------------------------------------------------------------------------------
SYMPTOMS
========
When you use the Net View command to view any computer from a multihomed
computer, the following error 52 message is returned:
A duplicate name detected on the network.
Also, Netstat -n shows the multihomed computer's own computer name in conflict.
CAUSE
=====
This problem may be caused by the following WINS configuration:
Each NIC in the multihomed computer points to a different primary WINS server.
Each WINS server thinks it is the owner for that computer's record and is not
registering the client correctly as a multihomed host.
RESOLUTION
==========
Disable WINS in one of the NICs, or set up both NICs to point to the same WINS
server.
Additional query words: name conflict duplicate multi-homed
======================================================================
Keywords :
Technology : kbWinNTsearch kbWinNTWsearch kbWinNTW400 kbWinNTW400search kbWinNT351search kbWinNT350search kbWinNT400search kbWinNTW350 kbWinNTW350search kbWinNTW351search kbWinNTW351 kbWinNTSsearch kbWinNTS400search kbWinNTS400 kbWinNTS351 kbWinNTS350 kbWinNTS351search kbWinNTS350search kbAudDeveloper kbWin95search kbWFWSearch kbZNotKeyword3 kbWFW311
Version : 3.50 3.51 4.00 95 3.11
=============================================================================