Article: Q172142
Product(s): Microsoft Windows NT
Version(s): WinNT:4.0
Operating System(s):
Keyword(s): kb3rdparty kbsetup
Last Modified: 09-AUG-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows NT Workstation versions 3.51, 4.0
- Microsoft Windows NT Server versions 3.51, 4.0
-------------------------------------------------------------------------------
SYMPTOMS
========
When you use Compaq's Insight Manager with Windows NT 3.51 or 4.0, it may
generate the following Event ID:
Event ID: 4129
Source: SysMgmt
Type: Error
Description: The Compaq Systems Management Driver has detected that an
application has passed a bad parameter to its Device IO Control routine.
CAUSE
=====
According to Compaq technical support, this error may be caused by a user mode
application sending a bad IOCTL packet to the Sysmgmt.sys driver. In addition,
this error has also been caused by bad or defective SCSI cables/connectors and
or improper termination.
RESOLUTION
==========
To correct the problem:
1. Verify that the latest SSD from Compaq is installed.
2. Verify proper cabling and termination on the SCSI Bus.
MORE INFORMATION
================
The Compaq products discussed here are manufactured by Compaq Computer Corp., a
vendor independent of Microsoft; we make no warranty, implied or otherwise,
regarding these products' performance or reliability.
Additional query words: prodnt
======================================================================
Keywords : kb3rdparty kbsetup
Technology : kbWinNTsearch kbWinNTWsearch kbWinNTW400 kbWinNTW400search kbWinNT351search kbWinNT400search kbWinNTW351search kbWinNTW351 kbWinNTSsearch kbWinNTS400search kbWinNTS400 kbWinNTS351 kbWinNTS351search