SYMPTOMS
========
When you try to install an Internet Information Server (IIS) node in Microsoft
Cluster Server, you may get the following error message:
An error occurred attempting to read properties for the
'IIS Server Instance' resource type:
More data is available.
Error ID: 234 (000000ea).
CAUSE
=====
This can occur if the two IIS installations reside on installations of Microsoft
Windows NT Server that are in different directories. For example, Computer 1 has
Windows NT installed in C:\Winnt, and Computer 2 has Windows NT installed in
C:\Winnt35. As a result, the Dlls files that are in the InetSrv directory are in
different places and the Cluster Server cannot find them on one of the two
systems.
WORKAROUND
==========
Make sure that both systems in the cluster have Windows NT installed into the
same directory.