Article: Q177778
Product(s): Microsoft Exchange
Version(s): winnt:5.0,5.5
Operating System(s):
Keyword(s):
Last Modified: 22-JUL-2000
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Exchange Server, versions 5.0, 5.5
-------------------------------------------------------------------------------
SYMPTOMS
========
The following events may be logged in the Application Event Log:
Event ID: 12000
Source: MSExchange NNTP
Type: Error
Category: Content Engine
Description: Error 80040C06-F2000312 occurred while processing
message <>.
Event ID: 11201
Source: MSExchange NNTP
Type: Error
Category: Client Action
Description: An unexpected error occurred while handling an NNTP
protocol command. Error 0x80040c06 was returned by procedure
EcWriteStream while executing procedure NNTPCON::EcReadArticle.
CAUSE
=====
A bi-directional pull feed connection has been set up from an upstream server.
When news is pulled down via that server and the articles include the header,
NNTP-Posting-Host, the downstream server tries to post these articles back to
the upstream server. The articles have the NNTP-Posting- Host header so the
upstream server rejects them. The header is tagged onto the articles coming in
to the upstream server when it receives those articles from its source, for
example, a client.
STATUS
======
This behavior is by design.
Additional query words:
======================================================================
Keywords :
Technology : kbExchangeSearch kbExchange500 kbExchange550 kbZNotKeyword2
Version : winnt:5.0,5.5
Issue type : kbbug
Solution Type : kbnofix
=============================================================================