Article: Q182631
Product(s): Microsoft SNA Server
Version(s): WINDOWS:1.0,4.0
Operating System(s):
Keyword(s):
Last Modified: 04-APR-2000
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft COM Transaction Integrator for CICS and IMS, version 1.0, used with:
- Microsoft SNA Server, version 4.0
-------------------------------------------------------------------------------
SUMMARY
=======
This article describes how to create a recording file that is capable of
capturing from a target Remote Environment (RE) which specifies a code page that
differs from the local machine default.
When a diagnostic capture RE is created using the COMTI Management Console, an
associated recording file is created. The code page assigned to the recording
file is the local default selected during Windows NT Server installation. If you
attempt to select a target RE on the Target property sheet that has a different
code page, the following error message appears:
(8022) The selected target Remote Environment uses a locale or code page
which is incompatible with the locale settings of the currently selected
recording file.
You may either modify the locale settings for the selected target Remote
Environment or identify a different recording file.
MORE INFORMATION
================
Diagnostic Capture RE's created with the COMTI Management Console are assigned
an Extended Binary Coded Decimal Interchange Code (EBCDIC) code page appropriate
for the current Windows NT Server system locale setting. To change this
assignment, you must create a new recording file with the preferred code page.
To modify a Diagnostic Capture RE so that it is capable of capturing from a
Target RE with a different code page, use the following steps:
1. Move any components that are currently assigned to the Diagnostic Capture RE
to another RE.
2. Right-click the Remote Environment and select Properties.
3. Click the Recording tab, and enter a new recording name in the Name field of
the Recording selection group box.
4. Click Browse and then click Open. Only the Type field should now be populated
in the Recording information group box. The remaining fields should be empty.
5. Click the Target tab and then click "Use responses from the following Remote
Environment."
6. Select the target RE you want to capture from. Click Apply to create the new
recording file. It will have the same code page as that of the Target RE.
7. Click the Local tab and view the Code page entry to verify.
To modify a Diagnostic Capture RE so that it has a specific code page, use the
following steps:
1. Move any components that are currently assigned to the Diagnostic Capture RE
to another RE.
2. Right-click the RE and select Properties.
3. Click the Recording tab and enter a new recording name in the Name field
under Recording Selection. The remaining fields should be empty.
4. Click the Target tab and then click "Use responses from the turnaround
dialog."
5. Click the Local tab and select the preferred code page.
6. Click Apply to create the new recording file with the preferred code page. If
you return to the Target tab and choose to capture from a target RE, its code
page must match that of the new recording file or the Apply will fail.
Additional query words:
======================================================================
Keywords :
Technology : kbAudDeveloper kbCOMTISearch
Version : WINDOWS:1.0,4.0
Hardware : ALPHA x86
Issue type : kbinfo
=============================================================================