Article: Q194082
Product(s): Microsoft SNA Server
Version(s): WINDOWS:3.0 SP1,3.0 SP2,3.0 SP3,4.0,4.0 SP1
Operating System(s):
Keyword(s): kbbuglist
Last Modified: 21-OCT-2000
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft SNA Server, versions 3.0 SP1, 3.0 SP2, 3.0 SP3, 4.0, 4.0 SP1
-------------------------------------------------------------------------------
SYMPTOMS
========
The APPC/CPI-C command TEST_RTS_AND_POST does not work when using a WinAsyncAppc
call. If the TEST_RTS_AND_POST verb is called asynchronously, the APPC library
signals the completion of the event but never receives the post event.
CAUSE
=====
TEST_RTS_AND_POST is one of the set of "post" APPC verbs which completes twice.
The TEST_RTS_AND_POST verb contains a post event. When the APPC library receives
the verb, it makes a note of this post event, and then completes the verb
immediately in the normal way, either by returning control to the application
(if called synchronously) or by signaling a completion event which has also been
supplied with the verb (if called asynchronously). Note that the completion
event is different from the post event which the verb contained.
This is the first completion for the verb.
Later, if the APPC library gets a change direction message from the SNA Server
service, it signals the post event.
This is the second completion of the verb.
The problem is that if the verb is called asynchronously, the APPC library
signals the first completion correctly, but for the second completion it signals
the completion event again, rather than the post event.
An application written to wait for the completion of the post event waits
forever, and the application thinks that a change direction message has never
been received by the APPC library.
RESOLUTION
==========
Microsoft has confirmed this to be a problem in SNA Server versions 3.0, 3.0
SP1, 3.0 SP2, 3.0 SP3, 4.0, and 4.0 SP1. We are researching this problem in SNA
Server version 3.0 and will post more information here in the Knowledge Base as
it becomes available.
This problem was corrected in the latest SNA Server version 4.0 U.S. Service
Pack. For information on obtaining this Service Pack, query on the following
word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words:
======================================================================
Keywords : kbbuglist
Technology : kbAudDeveloper kbSNAServSearch kbSNAServ400 kbSNAServ300SP3 kbSNAServ300SP1 kbSNAServ400SP1 kbSNAServ300SP2
Version : WINDOWS:3.0 SP1,3.0 SP2,3.0 SP3,4.0,4.0 SP1
Issue type : kbbug
Solution Type : kbfix
=============================================================================