SYMPTOMS
========
A Remote Control session will fail if either of the following conditions are
true:
- The Remote Control session is attempted from a Systems Management Server 2.0
Administrator Console to a Systems Management Server 2.0 client computer
while the client computer is running an application that uses DirectX.
-or-
- An application that uses DirectX is started on the client during the Remote
Control session.
This usually results in an exception error in Remote.exe -- access violation
(0xc0000005) -- on the Administrator Console computer, causing the Remote Tools
session to be disconnected, but it may also cause the Remote Control viewer on
the Administrator Console to stop responding.
WORKAROUND
==========
To work around this problem, do the following:
- Before attempting to start a Remote Control session, make sure that there are
no applications running on the Systems Management Server 2.0 client computer
that are using DirectX.
- Do not start any applications on the client that use DirectX while in the
Remote Control session.
STATUS
======
Microsoft has confirmed this to be a problem in Systems Management Server
version 2.0.