SYMPTOMS
========
When running ICA client against Windows NT Server 4.0, Terminal Server edition,
you may encounter the following stop screen error message:
Stop 0x0000007f (0x00000008, 0x00000000, 0x00000000, 0x00000000)
CAUSE
=====
There was a problem with the ICA Exception filter.
RESOLUTION
==========
To resolve this problem, obtain the latest service pack for Windows NT Server
4.0, Terminal Server Edition. For additional information, please see the
following article in the Microsoft Knowledge Base:
Q152734 How to Obtain the Latest Windows NT 4.0 Service Pack
STATUS
======
Microsoft has confirmed this to be a problem in Windows NT Server 4.0, Terminal
Server Edition. This problem was first corrected in Windows NT Server 4.0,
Terminal Server Edition Service Pack 4.