SYMPTOMS
========
Connection Manager cannot make a RAS connection using IPX/SPX.
CAUSE
=====
IPX/SPX is disabled by default in Connection Manager.
RESOLUTION
==========
To enable IPX, add the following lines to the <profilename>.cms file:
[Server&ProfileName]
Negotiate_IPX=1
Note: It may be necessary to add the Server&ProfileName heading to the .cms
file if it does not already exist.