SYMPTOMS
========
SNA LU3 printing does not support the following 3270 data stream orders:
- Start Field Extended (SFE, X'29')
- Set Attribute (SA, X'28")
- Modify Field (MF, X'2C')
The Start Field (SF, X'1D') order is converted to a blank (X'40').