SYMPTOMS
========

A run-time error is raised when an ActiveX component is recompiling in Visual
Basic, as follows.

When recompiling a Visual Basic ActiveX EXE or ActiveX DLL, the client
application may display the following error message:

  Run-Time Error '430':

  Class Does not support Automation or does not support expected interface

When a Visual Basic UserControl is recompiled, the client application may display
the following error message:

  Failed to activate control 'VB.UserControl'. This control may be incompatible
  with your application. Make sure that you are using the version of the
  control that was provided with your application.

CAUSE
=====

These errors occur if Public Methods or Properties are added to the ActiveX
component after making a copy for Binary Compatibility and then recompiling the
component a second time.

When new Public Methods or Properties are added to an ActiveX .exe, ActiveX .dll,
or a UserControl with Binary Compatibility set, Visual Basic adds a new
Interface to the second version for new client applications to use, and creates
a pointer from the old interface to the new Interface so that old clients
continue to work.

However, a problem occurs when a third version of this new ActiveX component is
compiled without resetting the Binary Compatible file to the second version of
the ActiveX .exe, .dll, or .ocx file. When this occurs, a new universally unique
identifier (UUID) and Interface are generated and any client applications
compiled against the second version fail.

RESOLUTION
==========

Ensure that the Binary Compatibility is always set to the latest version of your
ActiveX component, or a version that includes all Public Methods and Properties.

STATUS
======

This behavior is by design.

MORE INFORMATION
================

The following discussion uses an ActiveX .exe file as an example, but it should
be noted that the behavior for Interfaces is the same for all three types of
ActiveX components.

When you first compile an ActiveX .exe, ActiveX .dll, or UserControl (for
example, Server1.exe), Visual Basic creates an Interface for the Public Methods
and Properties, as follows:

+------------+
| Interface1 | 
+------------+
| Method1    | 
+------------+
| Method2    | 
+------------+
| Method3    | 
+------------+
| Property1  | 
+------------+
| Property2  | 
+------------+

If a new Method is added to the existing ActiveX .exe and Binary Compatibility is
set to Server1.exe, when the modified .exe is recompiled to Server2.exe, the
Interface structure is as follows:

+-------------------------------+
| Interface1 | --> | Interface2 | 
+-------------------------------+
|            |     | Method1    | 
+-------------------------------+
|            |     | Method2    | 
+-------------------------------+
|            |     | Method3    | 
+-------------------------------+
|            |     | Property1  | 
+-------------------------------+
|            |     | Property2  | 
+-------------------------------+
|            |     | Method4    | 
+-------------------------------+
|            |     | Property3  | 
+-------------------------------+

Calls on Interface1 are redirected to the correct Method or Property on
Interface2 for old clients. New clients automatically use Interface2.

This mechanism is transparent to the user and needs no special coding on the
client or the server.

If the .exe is compiled again without changing the file reference for binary
compatibility, (call it Server3.exe) then the following table is generated:

+-------------------------------+
| Interface1 | --> | Interface3 | 
+-------------------------------+
|            |     | Method1    | 
+-------------------------------+
|            |     | Method2    | 
+-------------------------------+
|            |     | Method3    | 
+-------------------------------+
|            |     | Property1  | 
+-------------------------------+
|            |     | Property2  | 
+-------------------------------+
|            |     | Method4    | 
+-------------------------------+
|            |     | Property3  | 
+-------------------------------+

Interface2 and Interface3 now have the same Methods but they are not the same
interface because they do not have the same UUID. This means that Server2.exe
and Server3.exe cannot be used interchangeably because they are not compatible
with each other. They are, however, both compatible with Server1.exe and can be
used with applications that are already compiled to use Server1.exe.

REFERENCES
==========

  Q161137 HOWTO: Use Project and Binary Compatibility

Additional query words: 430

======================================================================
Keywords          : kbActiveX kbCtrlCreate kbDLL kbInprocSvr kbLocalSvr kbVBp kbVBp600 kbGrpDSVB kbDSupport 
Technology        : kbVBSearch kbAudDeveloper kbZNotKeyword6 kbZNotKeyword2 kbVB600Search kbVBA600 kbVB600
Version           : WINDOWS:6.0
Issue type        : kbprb

=============================================================================