SYMPTOMS
========
Collections at a central site that are based on a query may not be correctly
replicated down to a child primary site if the query criteria does not exist on
the child site. In this situation, you may receive the following error messages
in the Colleval.log file:
Preparing to refresh collection DET00028
SQL Err #10007> General SQL Server error: Check messages from the SQL
Server
SQL Msg #208> Invalid object name 'User_Information_DATA'.
CCollectionSource_SQL::RefreshResults - Err in SQL cmd insert into
Temp__RES_COLL_DET00028 (MachineID,ArchitectureKey,Name,SMSID,Domain
,IsClient) select all SMS_R_System.ItemKey, SMS_R_System.DiscArchKey,
SMS_R_System.Name0, SMS_R_System.SMS_Unique_Identifier0,
SMS_R_System.Resource_Domain_OR_Workgr0, SMS_R_System.Client0 from
System_DISC AS SMS_R_System INNER JOIN User_Information_DATA AS
__RATION_USERINFORMATION_1_00 ON __RATION_USERINFORMATION_1_00.MachineID =
SMS_R_System.ItemKey where UPPER(__RATION_USERINFORMATION_1_00.Department00)
in (UPPER("092"),UPPER("091"),UPPER("094"))
$$<SMS_COLLECTION_EVALUATOR><Tue Apr 10 11:25:21.218 2001 Eastern
Standard Time><thread=2032 (0x7F0)>
CStatusReporter::Report() ERROR: Caller passed NULL for pSM.
Could not refresh collection DET00028. Will retry later.
CAUSE
=====
This behavior occurs if the NOIDMIF file's database class is not defined on the
child site. For example, assume the following hierarchy:
Central
/ \
/ \
/ \
Site A Site B
If Site A has implemented a NOIDMIF file, classes are created for both Site A and
the Central site. However, classes are not created for Site B, because inventory
only moves up the hierarchy. Therefore, when the Collection Evaluator on Site B
tries to evaluate a query based on these classes, the operation fails.
WORKAROUND
==========
To resolve this issue, put a copy of the NOIDMIF file that has been processed on
the parent site in the %windir%\MS\SMS\NOIDMIFS folder on a client in the child
site (for example, Site B, as described in the "Cause" section of this article).
To force a hardware inventory on the client, open the Systems Management tool in
Control Panel, click the Components tab, click Hardware Inventory, and then
click Start Component. A hardware inventory cycle starts on the client.
When the standard hardware processing cycle is complete, the NOIDMIF file is
appended to the hardware inventory and processed by the SMS Inventory Data
Loader on the child site. Classes in the inventory that do not exist in the
database are created. Collections can now be correctly evaluated.
MORE INFORMATION
================
When collections are replicated down to a child site, the membership rules are
replicated as a portion of the replicated data. If membership depends on a class
that does not exist at the child site, you may receive the error messages
described in the "Symptoms" section of this article.
For additional information about collection replication to child sites, see
chapter 17 of the Systems Management Server 2.0 Resource Guide.