SYMPTOMS
========
When you use a Microsoft Jet SQL query with a Visual Basic for Applications
(VBA) expression in it, the floating point unit (FPU) precision of an
application may be changed to 64 bits. For example, the SQL statement might
resemble the following:
Select Left([City],4) AS MyCity FROM Customers
CAUSE
=====
Most applications that are built with the C/C++ Run-time Library or with
Microsoft Visual Basic use the default 53-bit precision. However, when using Jet
queries you may find that the precision changes to 64 bits.
Expsrv.dll internally implements its own InitFP() function. This function calls
the FPU's FNINIT function, which changes the precision to 64 bits. InitFP() is
called at the initialization of the VBA expression service. The initialization
occurs when you first use a VBA-intrinsic function in a SQL statement. If your
application does not maintain a default workspace (for instance, an open
connection handle), InitFP is called each time that a connection is made to the
database. InitFP is also called when an exception occurs.
RESOLUTION
==========
To work around this problem, write your application to set FPU precision values
when needed.
For example, assume that you have a function which requires 53-bit precision
(doing some flointing point calls in the C runtime). You can change the
precision at the beginning of a function and then change it back at the end of
the scope of your function. To do this, you can write a helper C++ class that
sets the FPU precision on construction and resets it on destruction; for
example:
class C53Precision
{
DWORD m_dwOldPrecision;
public:
C53Precision(){
m_dwOldPrecision= _controlfp(0,0)&_MCW_PC;
_controlfp(_PC_53, _MCW_PC);
}
~C53Precision(){_controlfp(m_dwOldPrecision, _MCW_PC); }
};
The class constructor changes the precision to 53 bits, and the destructor
changes it back to the original precision.
Alternatively, because only Jet database calls which use VBA built-in functions
change the FPU precision, you can change the precision after those Jet calls;
for example:
CRecordset rs(&db);
rs.Open(CDatabase::dbDynaset, szSQL);
_controlfp(_PC_53, _MCW_PC); //Change the precision back to 53 bits.
For Visual C++ developers, another alternative is to use 64-bit precision
thoughout your application. You can do this by linking to fp10.obj, which
changes CRT's precision to 64 bits.
STATUS
======
Microsoft has confirmed this to be a bug in the Microsoft products listed at the
beginning of this article.
MORE INFORMATION
================
The following code reproduces this problem using Visual C++ and the JET ODBC
driver:
dwPrec= _control87( 0, 0)&_MCW_PC;
// dwPrec is PC_53 here.
CDatabase db;
db.OpenEx("DSN=accessdb");
CRecordset rs(&db);
rs.Open(CRecordset::dynaset , "Select Left([City],4) AS MyCity FROM Customers;");
dwPrec= _control87( 0, 0)&_MCW_PC;
// dwPrec is now PC_64.
The following code does not change the precsion because no VBA functions are used
in the query:
CDatabase db;
db.OpenEx("DSN=accessdb");
CRecordset rs(&db);
rs.Open(CRecordset::dynaset , "Select * from customers");
dwPrec= _control87( 0, 0)&_MCW_PC;
// dwPrec is PC_53.
Be aware that the precision terminology can be confusing; some documentation may
refer to total size of the floating point number whereas other documentation may
refer to precision bits:
_PC_24 (24 bits precision) (32 bit length)
_PC_53 (53 bits precision) (64 bit length) ---CRT's default value
_PC_64 (64 bits precision) (80 bit length) ---INTEL's default value
Also note that the FPU precision has thread affinity; changing the precision for
one thread does not change it for others.
Additional query words:
======================================================================
Keywords : kbGrpDSVCDB
Technology : kbVCsearch kbAudDeveloper kbMFC kbOLEDBSearch kbOLEDBProvJet351 kbOLEDBProvJet400 kbVC600 kbVC32bitSearch kbCRT kbOLEDBProvSearch
Version : :3.51,4.0,6.0
Issue type : kbbug
=============================================================================