Servers - Preventing false DDD
errors on hard drives |
Applicable
countries/regions |
Service hints
& tips |
Abstract Prevent false DDD
errors on server hard drives
Symptom Hard drives in
machine types 8640, 8641, 8642, and 9595 appear DDD. The
"Replace/Rebuild" function in the RAIDADM utility or on the
RAID Option Diskette completes successfully without physically
replacing the drive(s). No hardware failure actually occurs;
this is a false DDD.
Problem Isolation Aids The following hard
drives in both RAID and non-RAID Servers will be updated with
the firmware update:
1GB FRU p/n06H8560 (Option p/n
07H0386) 2GB FRU p/n06H8561 (Option p/n 07H0387) 4GB FRU
p/n06H8562 (Option p/n 07H0834)
The simplest way to
identify the drives is to remove the system cover and view the
front of the drives. These drives have a silver seal around
them.
Fix The IBM Hard Disk
Drive Update Utility Version 4.1 (C43.EXE) updates the
firmware on the silver hard drives connected to all IBM SCSI-2
adapters (including RAID adapters) and integrated SCSI-2
controllers supported in PC Servers except the ServeRAID
adapter (FRU p/n06H9334).
Obtain
a copy of this Diskette Servers manufactured with
the ServeRAID adapter do NOT require the hard drive update.
Hard drives with firmware 81K6 will be updated to 6C43. Hard
drives with firmware other than 81K6 will NOT be updated. The
firmware level of the drives can be viewed on the Drive
Information screen on Main Menu of RAID Option
Diskette.
Note: If dissimilar SCSI adapters
are installed, or if the Server has an integrated SCSI
controller (PCI/MicroChannel Servers) and a SCSI-2 adapter
(including RAID), then the utility will only update the hard
drives attached to the primary SCSI adapter. Therefore, the
utility must be run separately for each type of
adapter.
Follow this procedure: 1. Download
C43.EXE and expand the image onto a blank diskette using the
command: C43.EXE A: Obtain
a copy of this Diskette 2. Ensure that the customer
has a current backup of all data. 3. Shutdown the operating
system. 4. Boot the Server using the firmware
diskette. 5. An error message may appear as different
device drivers load. This is normal. Wait for the update to
complete. 6. Power off the Server. 7. If the Server has
dissimilar SCSI adapters or an integrated SCSI controller
(PCI/MCA systems), remove the primary SCSI adapter or disable
the integrated SCSI controller by moving the system board
jumper J26 to pins 2-3 (adapter position). Reboot the Server
using the firmware diskette and the drives connected to the
secondary adapter(s) will be updated. 8. After the update
is complete, remove the diskette and power off the
server. 9. Replace any adapters removed or return jumper
J26 to its original position.
Notes: 1. The
following message: "Hard Disk Drive updates complete. Remove
the diskette, turn off the system power and back on to
activate the update. Thank you." indicates that hard drives
connected to the PRIMARY (similar) SCSI adapter(s) were
updated. Make certain that hard drives connected to secondary
(dissimilar) SCSI adapter(s), if any, are also updated. See
step 7 above.
2. If the message "No hard disk drives
requiring firmware update are present" appears, then either no
hard drives require the update, OR the hard drives are
connected to secondary (dissimilar) adapter OR the integrated
SCSI controller (PCI/Microchannel Servers) needs to be
disabled. |
Document id: RMIE-39VBW5
|
Last modified: 2001-10-11
|
Copyright © 2002 IBM Corporation
| | |