IBM PC365 - Trap errors with IBM ISA ATM adapter

Applicable to: World-Wide

Symptom :
IBM PC 365 Series 6589 systems may exhibit various software related Trap errors in OS/2 while using an IBM ISA ATM 25 Network adapter.

Problem Isolation Aids :
Trap 0003 is the most common trap error exhibited by the system when using the ISA ATM adapter.

PCI versions of the IBM ATM adapters do not exhibit trap errors.

No failures have been reported using the ISA ATM 25 adapter with other operating systems.

Fix :
The combination of the IBM ISA ATM 25 Network adapter and the OS/2 device drivers is incompatible with the PC 365 Series 6589.

Customers experiencing failures with the adapter should be directed back to their point of purchase.