1.304 bytes |
Service Hints & Tips |
Document ID: SCOD-445ML5 |
Netfinity 3500 - Novell NetWare SFTIII
Applicable to: World-Wide
Abstract:
Netfinity 3500 in Novell NetWare SFTIII pair suffers hang/abend due to memory mismatch.
Symptom:
NetWare SFTIII reports memory mismatch or abends due to differing outputs from Mirrored Server Engine. Server pair are connected to dissimilar monitors.
Fix:
Advanced Graphic Port video configures system RAM according to type of monitor auto-detected. Use identical monitors or one monitor connected via a switch.