5.056 bytes

Service Hints & Tips

Document ID: MCGN-46VMEN

Servers - Rebuilding multi DDD drives across more than one array

Applicable to: World-Wide

Source: RETAIN tip H166102

Abstract:
Rebuilding multi DDD drives across more than one array.

Symptom:


Problem isolation aids:
The system is any of the following IBM servers:


The system is configured with one (1) or more of the following:


The system has multiple DDD drives.

The system has multiple arrays.

The system has Hot Swap Rebuild enabled.

The system has one of the DDD drives located at Channel 1, Drive ID 0.

All Firmware levels prior to and including 3.11 for the ServeRAID III, 2.88 for the ServeRAID II and onboard controllers, and 2.25 for the ServeRAID I.

The system's diagnostics pass.

Fix:
- This problem will be fixed in next BIOS/Firmware release.
- The target date for the release is scheduled for: May/June, 1999.
- It will be available from the following URL: http://www.pc.ibm.com/searchfiles.html Search on ServeRAID BIOS

Workaround:
In order to avoid this problem, do NOT replace the Channel 1, Drive ID 0 DDD drive first. Rebuild the other drive (wherever it might be), and upon its successful conclusion rebuild the DDD drive at Channel 1, Drive ID 0.

Details:
The default Hot Swap Rebuild program will look to rebuild to Channel 1, Drive ID 0. If multiple logical drives are in a Critical state, then they all will attempt to rebuild to the Channel 1, Drive ID 0 at the same time.

SAS keywords:
PSY2, NETFINITY, PCSERVER, UNCLASSIFIED, 7000-M10, D/T8680, 720, D/T8642, 7000, D/T8651, 520, D/T8641, 5500-M10, D/T8661, 5500, D/T8660, 330, D/T8640, 5000, D/T8659, 325, D/T8639, 3500, D/T8644, 320, D/T8640, 3000, D/T8476, 315, D/T8638, 704, D/T8650, 310, D/T8639, SERVERAID, BIOS, FIRMWARE, DRIVER, 70G8489, 76H3584, 01K7207, 01K7364

Search Keywords

Hint Category

RAID, Retain

Date Created

12-04-99

Last Updated

14-04-99

Revision Date

13-04-2000

Brand

IBM PC Server

Product Family

Netfinity 3000, Netfinity 3500, Netfinity 5000, Netfinity 5500, Netfinity 5500 M10, Netfinity 7000, Netfinity 7000 M10, PC Server 310, PC Server 315, PC Server 320, PC Server 325, PC Server 330, PC Server 520, PC Server 704, PC Server 720

Machine Type

8476, 8644, 8659, 8660, 8661, 8651, 8680, 8639, 8638, 8640, 8641, 8650, 8642

Model

TypeModel

Retain Tip (if applicable)

H166102

Reverse Doclinks
and Admin Purposes

Date last altered: A99/03/31