4.398 bytes |
Service Hints & Tips |
Document ID: MIGR-477KUJ |
Clustering - ServeRAID with MSCS: Drive rebuild process can stop
Applicable to: World-Wide
Source: RETAIN tip H166358
Abstract:
ServeRAID with MSCS: Drive rebuild process can stop.
Symptom:
If a drive rebuild is in process and a different ServeRAID cluster disk resource on the same SCSI channel is moved/failed over, the rebuild process could stop.
Note: You will be able to tell if the rebuilt process has stopped by the lack of a rebuild progress window from within the Windows NT ServeRAID administrator utility.
Problem isolation aids:
The system is any IBM server certified for MSCS and ServeRAID II or 3H.
Note: Currently shipping configurations are listed at the following URL:
http://www.pc.ibm.com/us/compat/clustering/matrix.shtml
Listed below are the shipping and non-shipping systems certified for MSCS:
- The system is configured with one of the following ServeRAID options:
The system is configured with Microsoft Windows NT 4.0 Enterprise, with any level Service Pack applied.
Fix:
This problem will be fixed in a future ServeRAID II and 3H BIOS/Firmware release.
It will be available from the following URL: http://www.pc.ibm.com/searchfiles.html
Search on ServeRAID BIOS.
Note: version should be later than v3.11
Workaround:
Restart the rebuild process. From the Windows NT ServeRAID Administrator utility, click on the drive in the RBL state, choose rebuild, then choose OK.
Trademarks:
Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States and/or other countries.
SAS keywords:
PSY2, NETFINITY, CLUSTER, UNCLASSIFIED, 5500-M20, D/T8662, 5500-M10, D/T8661, 5500, D/T8660, SERVERAID, 76H3584, 01K7207, 01K7364, FIRMWARE, BIOS
Search Keywords |
| |
Document Category |
Retain | |
Date Created |
22-04-99 | |
Last Updated |
06-05-99 | |
Revision Date |
06-05-2000 | |
Brand |
IBM PC Server | |
Product Family |
Netfinity 3500, Netfinity 5500, Netfinity 7000, PC Server 325, PC Server 330, PC Server 704, Netfinity 5000, Netfinity 7000 M10, Netfinity 5500 M10 | |
Machine Type |
8644, 8660, 8639, 8640, 8650, 8651, 8659, 8680, 8661 | |
Model |
All; 1RY; 2RY; 11Y; 21Y; RB0; PTW; PB0; PM0; PT0; PBW; PSW; PBS; PS0 | |
TypeModel |
| |
Retain Tip (if applicable) |
| |
Reverse Doclinks |