3.727 bytes

Service Hints & Tips

Document ID: MCGN-474MEX

Clustering - Microsoft Cluster Server and ServeRAID: IPSHAHTO.EXE may fail to move resources

Applicable to: World-Wide

Source: RETAIN tip H122173

Abstract: MSCS and ServeRAID: IPSHAHTO.EXE may fail to move resources

Symptom:
During the installation of Microsoft Cluster Server 1.0 (MSCS) and the IBM ServeRAID adapters the IPSHAHTO.EXE program may fail to move resources.

Problem isolation aids:
The system is any of the following IBM Netfinity servers:


Note: Supported configurations are listed at the following URL:
http://www.pc.ibm.com/us/compat/clustering/matrix.shtml Look for "Microsoft Cluster Server Configurations".

The system is configured with one or more of the following:


- The version 3.10 and 3.11 kit Device Driver for the ServeRAID III Adapter is affected.

- The system is configured with one or more of the following:


Fix:
Ensure all shared merge id's are consecutive. (i.e. 1,2,3 or 2,3,4 and NOT 2,4,6). IPSHAHTO.EXE will not work properly if the shared merge id's are not consecutive. If a customer requires the functionality, of using IPSHAHTO.EXE with non-consecutive shared merge id's, please contact the HelpCenter for an updated version of IPSHAHTO.EXE that resolves this problem. The updated version of IPSHAHTO.EXE will be included in the next release of the ServeRAID code.

Trademarks:
Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States and/or other countries. Other company, product and service names may be the trademarks or service marks of others.

SAS keywords:
PSY2, NETFINITY, CLUSTER, UNCLASSIFIED, 7000-M10, D/T8680, 5500-M10, D/T8661, 5500, D/T8660, 5000, D/T8659, IPSHAHTO.EXE, MSCS, SERVERAID, 01K7207, 01K7364

Search Keywords

Document Category

RAID, Retain

Date Created

19-04-99

Last Updated

18-05-99

Revision Date

Brand

IBM PC Server

Product Family

Clustering, Netfinity 5000, Netfinity 5500, Netfinity 5500 M10, Netfinity 5500 M20, Netfinity 7000 M10

Machine Type

Various, 8659, 8660, 8661, 8662, 8680

Model

TypeModel

Retain Tip (if applicable)

H122173

Reverse Doclinks
and Admin Purposes

Date last altered: A99/04/14