Netfinity 7000 M10 - Service Processor will take control of the shared port

Applicable to: World-Wide

Source: RETAIN tip H165149

Abstract: Service Processor will take control of the shared port

SYMPTOM:
If the Service Processor is rebooted using the Netfinity Manager, the Service Processor will take control of the shared communication port and this port will no longer be available for use. If connected to the Netfinity 7000 M10 remotely through a communication port, upon rebooting the Service Processor the connection will be lost.

PROBLEM ISOLATION AIDS:

- The system is a Netfinity 7000 M10 server, Type 8680, any model.
- The system's Diagnostics pass.
- The system has the described symptom.

FIX:
Next release of the Service Processor code will fix.

SAS KEYWORDS:
PSY2, D/T8680, NETFINITY, UNCLASSIFIED, SERVICE, PROCESSOR, COMM, 102681, PORT