Diagnostic Error Codes
In the following error codes, X can be any number or letter.

Error Code/Symptom

FRU/Action

001-XXX-XXX
(Failed core tests)

1. I/O Function Card
2. I/O Board

005-XXX-XXX
(Failed Video test)

1. I/O Function Card
2. I/O Board

011-XXX-XXX
(Failed Serial Port test)

1. I/O Function Card
2. I/O Board

014-XXX-XXX
(Failed Parallel Port test)

1. I/O Function Card
2. I/O Board

015-XXX-XXX
Failed USB test)

1. I/O Board

030-XXX-000
(Failed Internal SCSI interface test -channel 0)

1. I/O Function Card
2. I/O Board

030-XXX-001
(Failed Internal SCSI interface test -channel 1)

1. I/O Function Card
2. I/O Board

035-XXX-000
(Failed RAID test for adapter in slot 1)

1. SCSI Cable
2. RAID Adapter 1
3. SCSI Backplane

035-XXX-001
(Failed RAID test for Fixed Disk in bay 1 SCSI ID 0)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log.

1. Fixed Disk 1
2. SCSI Cable
3. RAID Adapter
4. SCSI Backplane

035-XXX-002
(Failed RAID test for Fixed Disk in bay 2 SCSI ID 1)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log.

1. Fixed Disk 2
2. SCSI Cable
3. RAID Adapter
4. SCSI Backplane

035-XXX-002
(Failed RAID test for adapter in slot 3)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log.

1. SCSI Cable
2. RAID Adapter 3
3. SCSI Backplane

035-XXX-003
(Failed RAID test for Fixed Disk in bay 3, SCSI ID 2)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log.

1. Fixed Disk 3
2. SCSI Cable
3. RAID Adapter
4. SCSI Backplane

035-XXX-003
(Failed RAID test for adapter in slot 4)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log.

1. SCSI Cable
2. RAID Adapter 4
3. SCSI Backplane

035-XXX-004
(Failed RAID test for Fixed Disk in bay 4, SCSI ID 3)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log.

1. Fixed Disk 4
2. SCSI Cable
3. RAID Adapter
4. SCSI Backplane

035-XXX-004
(Failed RAID test for adapter in slot 5)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log.

1. SCSI Cable
2. RAID Adapter 5
3. SCSI Backplane

035-XXX-005
(Failed RAID test for adapter in slot 6)

1. SCSI Cable
2. RAID Adapter 6
3. SCSI Backplane

035-XXX-006
(Failed RAID test for adapter in slot 7)

1. SCSI Cable
2. RAID Adapter 7
3. SCSI Backplane

035-XXX-007
(Failed RAID test for adapter in slot 8)

1. SCSI Cable
2. RAID Adapter 8
3. SCSI Backplane

035-XXX-008
(Failed RAID test for adapter in slot 9)

1. SCSI Cable
2. RAID Adapter 9
3. SCSI Backplane

035-XXX-009
(Failed RAID test for adapter in slot 10)

1. SCSI Cable
2. RAID Adapter 10
3. SCSI Backplane

035-XXX-010
(Failed RAID test for adapter in slot 11)

1. SCSI Cable
2. RAID Adapter 11
3. SCSI Backplane

035-XXX-011
(Failed RAID test for adapter in slot 12)

1. SCSI Cable
2. RAID Adapter 12
3. SCSI Backplane

089-XXX-001
(Failed Microprocessor test)

1. Processor 1
2. VRMs
3. Processor Board

089-XXX-002
(Failed Microprocessor test)

1. Processor 2
2. VRMs
3. Processor Board

089-XXX-003
(Failed Microprocessor test)

1. Processor 3
2. VRMs
3. Processor Board

089-XXX-004
(Failed Microprocessor test)

1. Processor 4
2. VRMs
3. Processor Board

165-XXX-000
(Failed System Management Card test)

1. System Management Card
2. System Management Card Cable
3. I/O Function Card

170-XXX-XXX
(Voltage sensor test failed)

1. System Management Card
2. System Management Card Cable
3. Power Control Card

175-XXX-XXX
(Thermal sensor test failed)

1. System Management Card
2. System Management Card Cable

180-XXX-000
(LED test failed)

1. System Management Card

180-XXX-001
(LED test failed)

1. Front Panel
2. System Management Card

180-XXX-002
(LED test failed)

1. Memory Card 1
2. System Management Card

180-XXX-003
(LED test failed)

1. Memory Card 2
2. System Management Card

180-XXX-004
(PCI Power/Attention LED tests failed)

1. I/O Board

180-XXX-005
(Retention bracket failure)

1. PCI Sensor Card
2. I/O Board

180-XXX-006
(ASPI not loaded)

1. SCSI Cable
2. SCSI Backplane
3. I/O Function Card

180-XXX-007
(DASD LED failed, see message for slot)

1. Cable
2. DASD backplane

185-XXX-001
(Intrusion Security test failed)

1. Intrusion (C2 Security) Cable
2. Front Panel
3. I/O Function Card

185-XXX-002
(Intrusion Security test failed)

1. Intrusion (C2 Security) Cable
2. Front Panel
3. I/O Function Card

201-004-CDD
(Failed Memory Test)
CDD:
C = Card number
DD = DIMM number (silk screened)

1. Memory DIMM
(see message for Card/DIMM)
2. Memory Card

201-204-999
(Failed memory test -multiple FRUs)

1. Memory DIMM
(see message for Card/DIMM)
2. Memory Card
(see message for Card/DIMM)

201-XXX-001
(Failed ECC test)

1. Memory DIMM
(Verify failing FRU in system error log.)

202-XXX-000
(Failed System Cache test)

1. BSP Processor
2. Processor Board

206-XXX-XXX
(Failed Diskette Drive test)

1. Diskette Drive cable
2. Diskette Drive
3. I/O Function Card

215-XXX-000
(Failed CD-ROM test)

1. CD-ROM cable
2. CD-ROM drive
3. I/O Board

217-XXX-001
(Failed BIOS Fixed Disk test)

1. Fixed Disk 1

217-XXX-002
(Failed BIOS Fixed Disk test)

1. Fixed Disk 2

217-XXX-003
(Failed BIOS Fixed Disk test)

1. Fixed Disk 3

217-XXX-004
(Failed BIOS Fixed Disk test)

1. Fixed Disk 4

301-XXX-XXX
(Failed Keyboard test)

1. Keyboard
2. I/O Function Card

415-XXX-XXX
(Failed modem test)

1. Modem Card



Search Keywords

Document Category

Diagnostics

Date Created

20-11-98

Last Updated

08-02-99

Revision Date

18-01-2000

Brand

IBM PC Server

Product Family

Netfinity 7000 M10

Machine Type

8680