Error Code/Symptom |
FRU/Action |
001-XXX-XXX
(Failed core tests) |
1. I/O Function Card
2. I/O Board |
005-XXX-XXX
(Failed Video test) |
1. I/O Function Card
2. I/O Board |
011-XXX-XXX
(Failed Serial Port test) |
1. I/O Function Card
2. I/O Board |
014-XXX-XXX
(Failed Parallel Port test) |
1. I/O Function Card
2. I/O Board |
015-XXX-XXX
Failed USB test) |
1. I/O Board |
030-XXX-000
(Failed Internal SCSI interface test -channel 0) |
1. I/O Function Card
2. I/O Board |
030-XXX-001
(Failed Internal SCSI interface test -channel 1) |
1. I/O Function Card
2. I/O Board |
035-XXX-000
(Failed RAID test for adapter in slot 1) |
1. SCSI Cable
2. RAID Adapter 1
3. SCSI Backplane |
035-XXX-001
(Failed RAID test for Fixed Disk in bay 1 SCSI ID 0)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log. |
1. Fixed Disk 1
2. SCSI Cable
3. RAID Adapter
4. SCSI Backplane |
035-XXX-002
(Failed RAID test for Fixed Disk in bay 2 SCSI ID 1)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log. |
1. Fixed Disk 2
2. SCSI Cable
3. RAID Adapter
4. SCSI Backplane |
035-XXX-002
(Failed RAID test for adapter in slot 3)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log. |
1. SCSI Cable
2. RAID Adapter 3
3. SCSI Backplane |
035-XXX-003
(Failed RAID test for Fixed Disk in bay 3, SCSI ID 2)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log. |
1. Fixed Disk 3
2. SCSI Cable
3. RAID Adapter
4. SCSI Backplane |
035-XXX-003
(Failed RAID test for adapter in slot 4)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log. |
1. SCSI Cable
2. RAID Adapter 4
3. SCSI Backplane |
035-XXX-004
(Failed RAID test for Fixed Disk in bay 4, SCSI ID 3)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log. |
1. Fixed Disk 4
2. SCSI Cable
3. RAID Adapter
4. SCSI Backplane |
035-XXX-004
(Failed RAID test for adapter in slot 5)
Important
This is a duplicate error code used for adapters and disk drives. To verify the type of failure, see the system error log. |
1. SCSI Cable
2. RAID Adapter 5
3. SCSI Backplane |
035-XXX-005
(Failed RAID test for adapter in slot 6) |
1. SCSI Cable
2. RAID Adapter 6
3. SCSI Backplane |
035-XXX-006
(Failed RAID test for adapter in slot 7) |
1. SCSI Cable
2. RAID Adapter 7
3. SCSI Backplane |
035-XXX-007
(Failed RAID test for adapter in slot 8) |
1. SCSI Cable
2. RAID Adapter 8
3. SCSI Backplane |
035-XXX-008
(Failed RAID test for adapter in slot 9) |
1. SCSI Cable
2. RAID Adapter 9
3. SCSI Backplane |
035-XXX-009
(Failed RAID test for adapter in slot 10) |
1. SCSI Cable
2. RAID Adapter 10
3. SCSI Backplane |
035-XXX-010
(Failed RAID test for adapter in slot 11) |
1. SCSI Cable
2. RAID Adapter 11
3. SCSI Backplane |
035-XXX-011
(Failed RAID test for adapter in slot 12) |
1. SCSI Cable
2. RAID Adapter 12
3. SCSI Backplane |
089-XXX-001
(Failed Microprocessor test) |
1. Processor 1
2. VRMs
3. Processor Board |
089-XXX-002
(Failed Microprocessor test) |
1. Processor 2
2. VRMs
3. Processor Board |
089-XXX-003
(Failed Microprocessor test) |
1. Processor 3
2. VRMs
3. Processor Board |
089-XXX-004
(Failed Microprocessor test) |
1. Processor 4
2. VRMs
3. Processor Board |
165-XXX-000
(Failed System Management Card test) |
1. System Management Card
2. System Management Card Cable
3. I/O Function Card |
170-XXX-XXX
(Voltage sensor test failed) |
1. System Management Card
2. System Management Card Cable
3. Power Control Card |
175-XXX-XXX
(Thermal sensor test failed) |
1. System Management Card
2. System Management Card Cable |
180-XXX-000
(LED test failed) |
1. System Management Card |
180-XXX-001
(LED test failed) |
1. Front Panel
2. System Management Card |
180-XXX-002
(LED test failed) |
1. Memory Card 1
2. System Management Card |
180-XXX-003
(LED test failed) |
1. Memory Card 2
2. System Management Card |
180-XXX-004
(PCI Power/Attention LED tests failed) |
1. I/O Board |
180-XXX-005
(Retention bracket failure) |
1. PCI Sensor Card
2. I/O Board |
180-XXX-006
(ASPI not loaded) |
1. SCSI Cable
2. SCSI Backplane
3. I/O Function Card |
180-XXX-007
(DASD LED failed, see message for slot) |
1. Cable
2. DASD backplane |
185-XXX-001
(Intrusion Security test failed) |
1. Intrusion (C2 Security) Cable
2. Front Panel
3. I/O Function Card |
185-XXX-002
(Intrusion Security test failed) |
1. Intrusion (C2 Security) Cable
2. Front Panel
3. I/O Function Card |
201-004-CDD
(Failed Memory Test)
CDD:
C = Card number
DD = DIMM number (silk screened) |
1. Memory DIMM
(see message for Card/DIMM)
2. Memory Card |
201-204-999
(Failed memory test -multiple FRUs) |
1. Memory DIMM
(see message for Card/DIMM)
2. Memory Card
(see message for Card/DIMM) |
201-XXX-001
(Failed ECC test) |
1. Memory DIMM
(Verify failing FRU in system error log.) |
202-XXX-000
(Failed System Cache test) |
1. BSP Processor
2. Processor Board |
206-XXX-XXX
(Failed Diskette Drive test) |
1. Diskette Drive cable
2. Diskette Drive
3. I/O Function Card |
215-XXX-000
(Failed CD-ROM test) |
1. CD-ROM cable
2. CD-ROM drive
3. I/O Board |
217-XXX-001
(Failed BIOS Fixed Disk test) |
1. Fixed Disk 1 |
217-XXX-002
(Failed BIOS Fixed Disk test) |
1. Fixed Disk 2 |
217-XXX-003
(Failed BIOS Fixed Disk test) |
1. Fixed Disk 3 |
217-XXX-004
(Failed BIOS Fixed Disk test) |
1. Fixed Disk 4 |
301-XXX-XXX
(Failed Keyboard test) |
1. Keyboard
2. I/O Function Card |
415-XXX-XXX
(Failed modem test) |
1. Modem Card |