2.423 bytes |
Service Hints & Tips |
Document ID: MCGN-3V6G8V |
Netfinity 5500 - OS watchdog doesn't reboot system after 2 successive OS hangs
Applicable to: World-Wide
Symptom:
If Novell has 2 successive system hangs, the OS watchdog timer will not detect the second hang and will NOT reboot the system.
Additional Details:
After the first reboot, the OS watchdog timer is not re-enabled. This is why subsequent hangs are not detected.
Fix:
In order for the watchdog to be re-enabled after one hang, the system must be re-booted via action taken by the customer. The customer will either have to power off the system locally or remotely via the Advanced Remote Management processor. See also Netfinity 5500 - OS watchdog timer reboots the system.
|
Search Keywords |
| |
|
Hint Category |
Other | |
|
Date Created |
05-06-98 | |
|
Last Updated |
30-03-99 | |
|
Revision Date |
30-03-2000 | |
|
Brand |
IBM PC Server | |
|
Product Family |
Netfinity 5500 | |
|
Machine Type |
8660 | |
|
Model |
11U; 11X; 41U; 41X; 1RU; 1RX; 4RU; 4RX; 42U; 42X; 51U; 51X; 52U; 52X; 5RU; 5RX; 4SU; 4SX; 5SU; 5SX | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
| |
|
Reverse Doclinks |