4.205 bytes

Service Hints & Tips

Document ID: DDSE-3R7JAS

This document is provided to IBM and our Business Partners to help sell and/or service IBM products. It is not to be distributed beyond that audience or used for any other purpose.

Server Options - 3518 - Symptoms to FRU Index

Applicable to: World-Wide

Symptom-to-FRU Index:
This index supports the PC Server Enterprise Expansion Enclosure (Type 3518).

The system management subsystem consists of a main processor that acts as the controller. The controller monitors the system temperature, the power supply, the fan rotation, and the system voltages. If a non-fatal error is detected, an error code or error message is displayed on the information panel. Fatal errors are logged to the system EEPROM and displayed at the next power-on.

Use this Symptom-to-FRU Index to help you decide which FRUs to have available when servicing the expansion enclosure.

Error Code/Symptom

FRU/Action

E700 AC Failure
(Power lost while the enclosure was running. The error is displayed
the next power-on.)

1. Power Cord
2. Power Supply

E701 Power Supply
(Redundant power supply indicates a bad condition. Error is non-fatal and can be cleared by pressing the front panel Enter button.)

1. Power Supply

E702 5V Failure
(Enclosure 5V input is low or too high. If too low, non-fatal error is written to the information panel. If to high, enclosure is shutdown and the error is displayed the next power-on.)

1. Power Supply
2. System Board (Planar)

703 12V Failure
(Enclosure 12V input is low or too high. If too low, non-fatal error is
written to the information panel. If to high, enclosure is shutdowns and the error is displayed the next power-on.)

1. Power Supply
2. System Board (Planar)

E704 Fan Failure
(In a non-fatal situation , a fan has failed. If multiple fans fail, the enclosure is shutdown and the enclosure will not run until the failure is
corrected.)

1. Fan
2. System Board (Planar)

E705 Overheat
(Power supply overheated and the enclosure was shutdown.)

1. Power Supply
2. Fan
3. System Board (Planar)

Blank information panel
(If the Power OK indicator is on and the fans are running, operation will probably not be affected. However, no diagnostic errors/messages will be displayed.)

1. Information Display Cable
2. Information Display Assembly
3. System Board (Planar)

No power
(Be sure the power cords and cables are properly plugged in, the expansion enclosure is properly enabled and powered on, and the
electrical power source is active.)

1. Power Cord
2. Power Supply



Search Keywords

Hint Category

Hardware Maintenance Information

Date Created

07-10-96

Last Updated

01-05-98

Revision Date

28-04-99

Brand

IBM PC Server

Product Family

Rack/Storage Enclosures

Machine Type

3518

Model

TypeModel

Retain Tip (if applicable)

N/A

Reverse Doclinks