2.139 bytes

Service Hints & Tips

Document ID: MCGN-3ZELLH

Netfinity 7000 M10 - "90" power system errors not reported on the front panel

Applicable to: World-Wide

Source: RETAIN tip H164907

SYMPTOM:
Errors created by over voltage conditions will not be displayed in the Front Panel although they are being logged in the System Error Log. On an abrupt system shut down due to a catastrophic failure, refer to the System Error Log (F1 at POST) and these errors will be seen.

PROBLEM ISOLATION AIDS:
- The system is a Netfinity 7000 M10 server, Type 8680, any model.

FIX:
The next level of SP code 31A will put the error message on the front panel.

WORKAROUND:
If failure occurs and system shuts down, you need to remove AC power to reset system.

SAS KEYWORDS:
PSY2, D/T8680, NETFINITY, UNCLASSIFIED, ERROR 90, H164907

Search Keywords

PSY2, D/T8680, NETFINITY, UNCLASSIFIED, ERROR 90, H164907

Hint Category

Retain

Date Created

19-10-98

Last Updated

14-01-99

Revision Date

14-01-2000

Brand

IBM PC Server

Product Family

Netfinity 7000 M10

Machine Type

8680

Model

ALL

TypeModel

Retain Tip (if applicable)

H164907

Reverse Doclinks
and Admin Purposes

Date last altered: A98/10/14