2.449 bytes

Service Hints & Tips

Document ID: RMIE-3GEAS2

PCServer500/720 - RAID Controller to Backplane Cable

Applicable to: World-Wide

Abstract:
8641/8642 RAID Controller to backplane cable

Text :
When troubleshooting RAID subsystem errors, including tape, hard drive, and CD-ROM errors on PC Server 500 (8641) and PC Server 720 (8642) RAID systems, do the following:

Inspect the four digit date code (ww/yy or wwyy) on the RAID controller to Backplane cable FRU p/n82G3613. If the date code is earlier than (13/95 or 1395), replace the cable with FRU p/n82g3613. Although the FRU number has not changed, the affected cables have been cleared from stock.

The first two numbers (ww) are the week and the second two numbers (yy) are the year of manufacture.

Cables manufactured before (13/95 or 1395) have end caps which may not be securely latched.

All current inventory should be dated (13/95 or 1395) and later.

SAS Keywords :
PSY2 PSY2PART PSY2ERR UNCLASSIFIED
DDD DEFUNCT D/T8642 ERROR

Search Keywords

Hint Category

Hard Drives, Retain

Date Created

23-04-97

Last Updated

22-01-99

Revision Date

14-05-99

Brand

IBM PC Server

Product Family

PC Server 500, PC Server 720

Machine Type

8641, 8642

Model

Various

TypeModel

Retain Tip (if applicable)

H137488

Reverse Doclinks