3.818 bytes

Service Hints & Tips

Document ID: GSMH-3AGEGD

IBM PC100 - 6281 Technical specifications

Applicable to: World-Wide

Specification (Type 6281)

Feature

Description

Size

Depth: 448 mm (17.6 in.)
Height: 160 mm (6.3 in.)
Width: 420 mm (16.5 in.)

Weight

Min. configuration: 12.7 kg (28.0 lb)
Maximum configuration: 14.1 kg (31.0 lb)5

Environment

Air temperature:
- System on: 10C to 32C (50F to 90F)
- System off: 10C to 43C (50F to 110F)
Humidity:
- System on: 8% to 80%
- System off: 8% to 80%
Maximum altitude: 2134 m (7000 ft)

Heat Output

Approximate heat output in BTUs perhour:
- Min. configuration: 120 BTU (35 watts)
- Max. configuration: 1060 BTU (310 watts)6
- Deep sleep: 15 BTU (4 watts)

Electrical Input

Sine-wave input (50 to 60 Hz) required.
Low range input voltage:
- Min.: 100 V ac
- Max.: 125 V ac
High range input voltage:
- Min.: 200 V ac
- Max.: 240 V ac
Input kVA (approximately):
- Min. configuration as shipped: 0.08 kVA
- Max. configuration: 0.52 kVA

Airflow

Approximately 0.56 cubic meters/minute (20 CFM)

Acoustical Noise Emission Values

Average sound pressure levels:
At operator position:
- 43 dB operating
- 43 dB idle
At bystander position (1 meter):
- 40 dB operating
- 40 dB idle Declared (upper limit) sound power levels:
- 5.0 bels operating
- 4.8 bels idle


5 Maximum configuration weight depends on options installed.
Figures above are a system fully populated with options.

6 Maximum power and heat specifications are based on the
200-watt maximum capacity of the system power supply.

7 For additional information, see the ISO Supplier's Declaration
available from IBM.

Search Keywords

Hint Category

Hardware Maintenance Information

Date Created

16-05-96

Last Updated

14-05-98

Revision Date

23-04-99

Brand

IBM PC

Product Family

PC 100

Machine Type

6281

Model

all

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes