4.500 bytes |
Product Information |
Document ID: DDSE-42ZPUG |
Netfinity 5500 - System Board LEDs and System Board SCSI LEDs
Applicable to: World-Wide
System Board LEDs
The system board contains three SCSI LEDs and a processor LED that are turned on when the system detects an error.
Notes |
System Board LED |
FRU/Action |
Service Processor LED |
1. System Board |
SCSI LED(s) on |
1. See "System Board SCSI LEDs." |
Notes |
System Board SCSI LEDs |
FRU/Action |
1 blink followed by a pause |
1. Check cables |
2 blinks followed by a pause |
1. Check cables |
3 blinks followed by a pause |
1. Run the ServeRAID Flash program. |
4 blinks followed by a pause |
1. Check cables |
5 blinks followed by a pause |
a. Check cables |
6 blinks followed by a pause |
1. Run the ServeRAID Flash program. |
On (solid) |
1. Check jumper J11, see "System Board Jumpers". |
Search Keywords |
| |
Document Category |
Diagnostics | |
Date Created |
09-12-98 | |
Last Updated |
09-12-98 | |
Revision Date |
09-12-99 | |
Brand |
IBM PC Server | |
Product Family |
Netfinity 5500 | |
Machine Type |
8660 | |
Model |
ALL | |
TypeModel |
| |
Retain Tip (if applicable) |
| |
Reverse Doclinks |