4.500 bytes

Product Information

Document ID: DDSE-42ZPUG

Netfinity 5500 - System Board LEDs and System Board SCSI LEDs

Applicable to: World-Wide

System Board LEDs
The system board contains three SCSI LEDs and a processor LED that are turned on when the system detects an error.

Notes
1. To locate the LEDs on the system board see "System Board Component Locations".
2. Check the system error log for additional information before replacing a FRU.


System Board LED

FRU/Action

Service Processor LED

1. System Board

SCSI LED(s) on
(Blinking or solid)

1. See "System Board SCSI LEDs."



System Board SCSI LEDs
A solid on or blinking system board SCSI LED indicated an error was detected. (The blinks are followed by a pause.)

Notes
1. To locate the LEDs on the system board see "System Board Component Locations".
2. If you are instructed to flash the ServeRAID controller on the system board, refer to the ServerGuide
that was shipped with the system for instructions on creating a bootable ServeRAID Flash diskette.
Or refer to the WEB, see "Online Support".
3. Check the system error log for additional information before replacing a FRU.




System Board SCSI LEDs

FRU/Action

1 blink followed by a pause
(Boot block checksum error)

1. Check cables
2. System Board
3. DASD Backplane

2 blinks followed by a pause
(DRAM parity error)

1. Check cables
2. System Board
3. DASD Backplane

3 blinks followed by a pause
(Code block checksum error, flash the ServeRAID
controller.)

1. Run the ServeRAID Flash program.
2. Check cables
3. System Board
4. DASD Backplane

4 blinks followed by a pause
(DRAM DATA)

1. Check cables
2. System Board
3. DASD Backplane

5 blinks followed by a pause
(DRAM address error)

a. Check cables
b. System Board
c. DASD Backplane

6 blinks followed by a pause
(Code block checksum error, flash the ServeRAID
controller.)

1. Run the ServeRAID Flash program.
2. Check cables
3. System Board
4. DASD Backplane

On (solid)

1. Check jumper J11, see "System Board Jumpers".
2. Check cables
3. System Board
4. DASD Backplane



Search Keywords