2.596 bytes

Service Hints & Tips

Document ID: MCGN-3ZEJBB

Netfinity 5500 - Remote connection lost when running diagnostics

Applicable to: World-Wide

Source: RETAIN tip H164905

SYMPTOM:
When Netfinity 5500 diagnostics, version 2.00, is run remotely and "Run Quick Test" is selected, the remote connection will be lost during the test. This occurs when the "Restart Service Processor Test" runs which resets the remote connection being handled by the service processor.

PROBLEM ISOLATION AIDS:
- The system is a Netfinity 5500 server, Type 8660, any model.

- The system has the symptom described.

FIX:
In diagnostic version 2.01 the "Run Quick Test" will be altered to not include "Restart Service Processor Test". When this change is made, it will be fine to run "Run Quick Test" remotely.

WORKAROUND:
When running diagnostics remotely, do not select the "Run Quick Test".

DETAILS:
In the "Run Quick Test" of the diagnostics is included a "Service Processor Test". A subset of the "Service Processor Test" is a "Reset Service Processor Test". This test will reset the service processor which is handling the remote connection.

SAS KEYWORDS:
PSY2, D/T8660, NETFINITY, UNCLASSIFIED, 8660DIAG, DIAG, DIAGNOSTIC, SERVICE, PROCESSOR, H164905

Search Keywords

PSY2, D/T8660, NETFINITY, UNCLASSIFIED, 8660DIAG, DIAG, DIAGNOSTIC, SERVICE, PROCESSOR, H164905

Hint Category

Retain, Service Processor

Date Created

19-10-98

Last Updated

14-01-99

Revision Date

14-01-2000

Brand

IBM PC Server

Product Family

Netfinity 5500

Machine Type

8660

Model

ALL

TypeModel

Retain Tip (if applicable)

H164905

Reverse Doclinks
and Admin Purposes

Date last altered: A98/10/13