20.561 bytes

Service Hints & Tips

Document ID: MCGN-3QYN8W

PCServer330 - RAID POST Error Codes

Applicable to: World-Wide

RAID POST Error Codes

Once the RAID test has completed the following register information is displayed on the screen before returning to the Diagnostic Control program:
Hdwr: ISPR= aaaa BCS= bb ECS= cc

The number aaaa is the controller POST, it should normally read EF10 which indicates NO ERROR. BCS and ECS are configuration registers.

Note
For a full list of the BCSúECS configuration error
messages, refer to the manual for the RAID adapter.


Error Code

FRU/Action

1XXX
ServeRAID POST - Flash
Checksum error

1. System Board

2XXX
ServeRAID POST - Code
DRAM error

1. System Board

3XXX
ServeRAID POST - NVRAM
error

1. System Board

4XXX
ServeRAID POST -Timer/
Cache Mem Ctl error

1. System Board

5XXX
ServeRAID POST - Cache
Mem Ctl error

1. System Board

6XXX
ServeRAID POST - Cache
DRAM error

1. System Board

7XXX
ServeRAID POST -Host/
Local PCI Bus Interface error

1. System Board

8XXX
ServeRAID POST - SCSI
IOP error

1. System Board

9XXX
ServeRAID POST - SCSI
Termination error

1. System Board

AXXX
ServeRAID POST - SCSI
IOP error

1. System Board

BXXX
ServeRAID POST - SCSI
Bus Interface error

1. Cable
2. System Board




RAID Diagnostic Error Codes

Error Code

FRU/Action

2601h
Adapter never came back
from res

1. System Board

2602h
CBSP OP bit = 0

1. System Board

2603h
ISPR not = 0EF10h

1. System Board

2604h
Unable to get 2'nd ISPR
byte

1. System Board

2605h
Timeout of clr HISR

1. System Board

2606h
Timeout of 2'nd read of
HISR

1. System Board

2607h
BCS bit VBC not = 1

1. System Board

2608h
CBSP OP bit not = 0

1. System Board

2609h
PCI BIOS Error

1. System Board

260Ah
No PCI BIOS found

1. System Board

260Bh
Adapter never came back
from res

1. System Board

2610h
ServeRAID POST Error -RAID
Controller Hardware problem

1. System Board

2620h
RAID Configuration Error -Disk
Configuration or Hard
Disk problem

1. System Board




Error Code 7219h
Error code 7219h returns the following additional information in the failing data field.

Failing Data

Description

19010101

Error setting dma channel

19010102

Error setting IRQ

19020201

Ethernet chip did not respond to initialization

19020202

Ethernet chip status error

19020203

Ethernet chip initialization did not complete

1903xxyy

Error in Ethernet loop-back test (xxyy = number of completed transmit and received data packets)




BCS/ECS Configuration Registers

Codes

BCS

ECS

Explanation and
Possible
Recovery Action

BCS not in table

ECS not in table

Explanation: The adapter is not functioning properly.
Action: Run ServeRAID diagnostics and display message M4.

0000 0000
(X'00')

0000 0001
(X'01')

Explanation: Invalid Flash configuration.
Action: Run ServeRAID configuration and display message M2.

0000 0000
(X'00')

0000 0010
(X'02')

Explanation: Invalid NVRAM configuration.
Action: Run ServeRAID configuration and display message M2.

0000 0000
(X'00')

0000 0011
(X'03')

Explanation: Invalid Flash and NVRAM configuration.
Action: Run ServeRAID configuration and display message M3.

0000 0001
(X'01')

0000 1000
(X'08')

Explanation: No configuration was found in drive(s) and ONL/RBL drive(s) are not responding.
Action: Press F1, F2, F4, F10

0000 0001
(X'01')

0001 1000
(X'18')

Explanation: No configuration was found in drive(s) and ONL/RBL and HSP/SHS drive(s)
are not responding.
Action: Press F1, F2, F4, F10

0000 0001
(X'01')

0010 1000
(X'28')

Explanation: No configuration was found in drive(s) and ONL/RBL and RDY/SBY drive(s)
are not responding.
Action: Press F1, F2, F4, F10

0000 0001
(X'01')

0011 1000
(X'38')

Explanation: No configuration was found in drive(s) and ONL/RBL, HSP/SHS, and
RDY/SBY drive(s) are not responding.
Action: Press F1, F2, F4, F10

0000 0001
(X'01')

0100 1000
(X'48')

Explanation: No configuration was found in drive(s) and ONL/RBL drive(s) are not responding and unidentified drive(s) were found.
Action: Press F1, F2, F4, F10

0000 0001
(X'01')

0101 1000
(X'58')

Explanation: No configuration was found in drive(s) and ONL/RBL and HSP/SHS drive(s)
are not responding and unidentified drive(s) were found.
Action: Press F1, F2, F4, F10

0000 0001
(X'01')

0110 1000
(X'68')

Explanation: No configuration was found in drive(s) and ONL/RBL and RDY/SBY drive(s)
are not responding and unidentified drive(s) were found.
Action: Press F1, F2, F4, F10

0000 0001
(X'01')

0111 1000
(X'78')

Explanation: No configuration was found in drive(s) and ONL/RBL, HSP/SHS, and
RDY/SBY drive(s) are not responding and unidentified drive(s) were found.
Action: Press F1, F2, F4, F10

0000 0011
(X'03')

1000 1000
(X'88')

Explanation: A drive was imported from another system and it has valid configuration and ONL/RBL drive(s) are not responding.
Action: Press F1, F2, F4, F10

0000 0011
(X'03')

1001 1000
(X'98')

Explanation: A drive was imported from another system and it has valid configuration and ONL/RBL and HSP/SHS drive(s) are not responding.
Action: Press F1, F2, F4, F10




BCS

ECS

Explanation and
Possible
Recovery Action

0000 0011
(X'03')

1010 1000
(X'A8')

Explanation: A drive was imported from another
system and it has valid configuration and ONL/RBL and RDY/SBY drive(s) are not responding.
Action: Press F1, F2, F4, F10

0000 0011
(X'03')

1011 1000
(X'B8')

Explanation: A drive was imported from another
system and it has valid configuration and ONL/RBL, HSP/SHS, and RDY/SBY drive(s)
are not responding.
Action: Press F1, F2, F4, F10

0000 0011
(X'03')

1100 1000
(X'C8')

Explanation: A drive was imported from another
system and it has valid configuration and ONL/RBL drive(s) are not responding and
unidentified drive(s) were found.
Action: Press F1, F2, F4, F10

0000 0011
(X'03')

1101 1000
(X'D8')

Explanation: A drive was imported from another
system and it has valid configuration and ONL/RBL and HSP/SHS drive(s) are not responding and unidentified drive(s) were
found.
Action: Press F1, F2, F4, F10

0000 0011
(X'03')

1110 1000
(X'E8')

Explanation: A drive was imported from another
system and it has valid configuration and ONL/RBL and RDY/SBY drive(s) are not responding and unidentified drive(s) were
found.
Action: Press F1, F2, F4, F10

0000 0011
(X'03')

1111 1000
(X'F8')

Explanation: A drive was imported from another
system and it has valid configuration and ONL/RBL, HSP/SHS, and RDY/SBY drive(s)
are not responding and unidentified drive(s) were
found.
Action: Press F1, F2, F4, F10

0000 0111
(X'07')

0000 1000
(X'08')

Explanation: ONL/RBL drive(s) are not responding.
Action: Press F1, F2, F10

0000 0111
(X'07')

0000 1100
(X'0C')

Explanation: ONL/RBL drive(s) are not responding and drive in wrong ID.
Action: Press F1, F2, F3, F10

0000 0111
(X'07')

0001 1000
(X'18')

Explanation: ONL/RBL and HSP/SHS drive(s)
are not responding.
Action: Press F1, F2, F10

0000 0111
(X'07')

0001 1100
(X'1C')

Explanation: ONL/RBL and HSP/SHS drive(s)
are not responding and drive in wrong ID.
Action: Press F1, F2, F3, F10

0000 0111
(X'07')

0010 1000
(X'28')

Explanation: ONL/RBL and RDY/SBY drive(s)
are not responding.
Action: Press F1, F2, F10

0000 0111
(X'07')

0010 1100
(X'2C')

Explanation: ONL/RBL and RDY/SBY drive(s)
are not responding and drive in wrong ID.
Action: Press F1, F2, F3, F10

0000 0111
(X'07')

0011 1000
(X'38')

Explanation: ONL/RBL, RDY/SBY, and
HSP/SHS drive(s) are not responding.
Action: Press F1, F2, F10

0000 0111
(X'07')

0011 1100
(X'3C')

Explanation: ONL/RBL, RDY/SBY, and
HSP/SHS drive(s) are not responding and drive in wrong ID.
Action: Press F1, F2, F3, F10

0000 0111
(X'07')

0100 1000
(X'48')

Explanation: ONL/RBL drive(s) are not responding and unidentified drive(s) were
found.
Action: Press F1, F2, F10

0000 0111
(X'07')

0100 1100
(X'4C')

Explanation: ONL/RBL drive(s) are not responding, drive in wrong ID, and unidentified
drive(s) were found.
Action: Press F1, F2, F3, F10

0000 0111
(X'07')

0101 1000
(X'58')

Explanation: ONL/RBL and HSP/SHS drive(s)
are not responding and unidentified drive(s) were
found.
Action: Press F1, F2, F10

0000 0111
(X'07')

0101 1100
(X'5C')

Explanation: ONL/RBL and HSP/SHS drive(s)
are not responding, drive in wrong ID, and unidentified drive(s) were found.
Action: Press F1, F2, F3, F10

0000 0111
(X'07')

0110 1000
(X'68')

Explanation: ONL/RBL and RDY/SBY drive(s)
are not responding and unidentified drive(s) were
found.
Action: Press F1, F2, F10

0000 0111
(X'07')

0110 1100
(X'6C')

Explanation: ONL/RBL and RDY/SBY drive(s)
are not responding, drive in wrong ID, and unidentified drive(s) were found.
Action: Press F1, F2, F3, F10

0000 0111
(X'07')

0111 1000
(X'78')

Explanation: ONL/RBL, RDY/SBY, and
HSP/SHS drive(s) are not responding and unidentified drive(s) were found.
Action: Press F1, F2, F10

0000 0111
(X'07')

0111 1100
(X'7C')

Explanation: ONL/RBL, RDY/SBY, and
HSP/SHS drive(s) are not responding, drive in wrong ID, and unidentified drive(s) were found.
Action: Press F1, F2, F3, F10

0000 1001
(X'09')

0000 0000
(X'00')

Explanation: No error occurred.
Action: None

0000 1001
(X'09')

0001 0000
(X'10')

Explanation: HSP/SHS drive(s) are not responding.
Action: Press F1, F2, F10

0000 1001
(X'09')

0010 0000
(X'20')

Explanation: RDY/SBY drive(s) are not responding.
Action: Press F1, F2, F10

0000 1001
(X'09')

0011 0000
(X'30')

Explanation: HSP/SHS and RDY/SBY drive(s)
are not responding.
Action: Press F1, F2, F10

0000 1111
(X'0F')

0000 0000
(X'00')

Explanation: No error occurred.
Action: None

0000 1111
(X'0F')

0001 0000
(X'10')

Explanation: HSP/SHS drives are not responding.
Action: Press F1, F2, F10

0000 1111
(X'0F')

0010 0000
(X'20')

Explanation: RDY/SBY drives are not responding.
Action: Press F1, F2, F10

0000 1111
(X'0F')

0011 0000
(X'30')

Explanation: HSP/SHS and RDY/SBY drive(s)
are not responding.
Action: Press F1, F2, F10



Search Keywords

Hint Category

Error Messages, Hard Drives, Hardware Maintenance Information

Date Created

22-01-98

Last Updated

25-01-99

Revision Date

24-01-2000

Brand

IBM PC Server

Product Family

PC Server 330

Machine Type

8640

Model

11Y; 21Y; PB0; PM0; PT0

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes