3.706 bytes |
Service Hints & Tips |
Document ID: LWIK-3NHMRK |
TP 760 - Diskette drive test
Applicable to: World-Wide
The following information is intended for IBM Dealers and Authorized Servicers only. Customers attempting to follow any of the procedures below may void their warranty.
Diskette Drive Test :
Do the following to isolate the problem to a controller, drive, or diskette. A scratch, write enabled, non-defective 2HD diskette is required.
FDD-1 represents the the diskette drive in the UltraBay. FDD-2 represents the port replicator, expansion unit, or diskette drive attached through the external diskette drive connector.
Warning : Make sure that the diskette does not have more than one label attached to it. Multiple labels can cause damage to the drive or can cause the drive to fail.
Do the following to select the test device:
1. Select the advanced diagnostics mode and select Tool ; then select the FDD-1 or FDD-2 icon and press the spacebar.A mark appears next to the selected icon. Insert the blank diskette when instructed.
2. Run the diskette drive test.
3. If the controller test detects an error, FRU code 10 appears. Replace the system board.
4. If the controller test runs without errors, the drive read/write tests start automatically.
5. If the drive test detects an error, FRU code 50 for FDD-1 or 51 for FDD-2 appears. If the diskette itself is known to be good, replace the drive.
6. If FDD-2 test detects an error, move the drive to the computer's diskette drive connector directly, if possible, and test it again as FDD-1.
If no errors occur in the FDD-1 position, the drive is not defective.
7. If the drive is attached through an Expansion Unit, go to the service manual of the Expansion Unit to isolate the problem.
8. If the drive is attached through a Diskette Drive Attachment Unit, replace the unit.
If an error occurs when the external diskette drive is attached through the external diskette drive connector and there is not a diskette drive in the UltraBay, reseat the connector on the video card. If the error still remains, reseat the external diskette drive connector.
If the error still remains, replace the following FRUs one at a time.
1. External diskette drive kit
2. Video card
3. External diskette drive connector
Search Keywords |
| |
Hint Category |
Hardware Maintenance Information | |
Date Created |
31-07-96 | |
Last Updated |
19-08-98 | |
Revision Date |
18-08-99 | |
Brand |
IBM ThinkPad | |
Product Family |
ThinkPad 760C, ThinkPad 760E, ThinkPad 760CD, ThinkPad 760L/LD, ThinkPad 760ED, ThinkPad 760XD, ThinkPad 760EL/ELD, ThinkPad 760XL | |
Machine Type |
9546, 9547 | |
Model |
Various | |
TypeModel |
| |
Retain Tip (if applicable) |
| |
Reverse Doclinks |