4.710 bytes

Product Information

Document ID: MCGN-45VRLT

Netfinity 5500 M20 - Error Symptoms

Applicable to: World-Wide

Source: Hardware Maintenance Manual

Error Symptoms

Error Symptom

FRU/Action

CD is not working properly.

1. Clean the CD
2. CD-ROM Drive

CD-ROM drive tray is not working.
(The server must be powered-on.)

1. Insert the end of a paper clip into the manual tray-release opening.
2. CD-ROM Drive

CD-ROM drive is not recognized.

1. Run Configuration/Setup, enable primary IDE channel.
2. Check cables and jumpers.
3. Check for correct device driver.

Power switch does not work and reset button
does work.

1. Verify that the power-on control jumper on J32's extension cable is on pins 1 and 2.
2. Power Switch Assembly
3. System Board

Diskette drive in-use light stays on, or the system
bypasses the diskette drive, or the diskette drive
does not work.

If there is a diskette in the drive, verify that:
1. The diskette drive is enabled in the configuration
programs.
2. The diskette is good and not damaged.
(Try another diskette if you have one.)
3. The diskette is inserted correctly in the drive.
4. The diskette contains the necessary files to start the
server.
5. The software program is OK.
6. Run Diskette Drive Diagnostics.
7. Cable
8. Diskette Drive
9. System Board

Monitor problems (general)
Some IBM monitors have their own self-tests.
If you suspect a problem with your monitor,
refer to the information that comes with the monitor
for adjusting and testing instructions.

1. Monitor
2. Run Video Diagnostics. If diagnostics pass, the problem may be a video driver.
3. Display Adapter/System Board



Search Keywords

Document Category

Diagnostics

Date Created

11-03-99

Last Updated

16-03-99

Revision Date

26-05-2000

Brand

IBM PC Server

Product Family

Netfinity 5500 M20

Machine Type

8662

Model

All

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes