2.050 bytes |
Service Hints & Tips |
Document ID: DETR-43ENFE |
This document is provided to IBM and our Business Partners to help sell and/or service IBM products. It is not to be distributed beyond that audience or used for any other purpose. |
Aptiva - 2163/2164 Considerations - System hangs due to lightning strike of 1KV or greater
Applicable to: World-Wide
Description:
With API power supply, system hangs during a lightning strike of 1KV or more.
Models affected:
2163 and 2164
How to duplicate:
System powered on during nearby lightning strike.
Root cause:
Failing stress condition is E4 1.2uS rise time, 50uS duration 2KV line to ground. System passes with no errors at 900V but locks up at 1KV or higher.
Workaround:
Rebooting will recover. H/W EC to the planar will be phased in by 1/99 or earlier.
Search Keywords |
| |
Hint Category |
Power, Considerations, Lock-up/Hang | |
Date Created |
22-12-98 | |
Last Updated |
02-03-99 | |
Revision Date |
01-03-2000 | |
Brand |
IBM Aptiva | |
Product Family |
Aptiva | |
Machine Type |
2163, 2164 | |
Model |
all | |
TypeModel |
| |
Retain Tip (if applicable) |
| |
Reverse Doclinks |